Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system

被引:5
|
作者
Sasaki Y. [1 ]
Abe K. [2 ]
Tabei M. [3 ]
Katsuragawa S. [4 ]
Kurosaki A. [5 ]
Matsuoka S. [1 ]
机构
[1] Department of Radiology, Iwate Prefectural Central Hospital, Morioka 020-0066
[2] Department of Radiology, School of Medicine, Nihon University, Itabashi-Ku, Tokyo 173-8610
[3] Medical Systems Business Division, FUJIFILM Medical, Minato-Ku, Tokyo 106-8620
[4] Department of Medical Physics, School of Health Sciences, Kumamoto University, Kumamoto 862-0976
[5] Department of Radiology, Toranomon Hospital, Minato-Ku, Tokyo 105-8470
关键词
Computed radiography; Digital radiography; Lung cancer screening; ROC analysis; Temporal subtraction image;
D O I
10.1007/s12194-010-0109-7
中图分类号
学科分类号
摘要
The temporal subtraction image which is obtained by subtraction of a previous image from a current image of the same patient can enhance interval changes. In this study, we applied the temporal subtraction method for lung cancer screening and evaluated the clinical usefulness by comparing the review time and the detection accuracy of lung cancers without and with subtraction images. Since 1996, we have been performing screening chest radiography for a mass survey of lung cancers in the Iwate Prefecture, Japan, by using a van equipped with a computed radiography system and a digital archive system. During the 12 years from 1997 to 2008, a total of 186,340 examinations were performed, and 121,526 (65.2%) temporal subtraction images were provided in the lung cancer screening. Twenty-four abnormal cases with lung cancer and 270 normal cases were selected from the lung cancer screening. Five radiologists participated in an observer performance study and interpreted previous and current chest radiographs without and with temporal subtraction images. In addition, radiologists interpreted previous and current images with a double-reading method. The average ROC curves demonstrated a significant improvement in the detection accuracy of lung cancers with the temporal subtraction images compared with that without the temporal subtraction images, and that with the double-reading method. Therefore, we believe strongly that the temporal subtraction method is clinically useful for radiologists in the detection of lung cancers in mass surveys. © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:84 / 90
页数:6
相关论文
共 50 条
  • [21] An investigation of automatic exposure control calibration for chest imaging with a computed radiography system
    Moore, C. S.
    Wood, T. J.
    Avery, G.
    Balcam, S.
    Needler, L.
    Beavis, A. W.
    Saunderson, J. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09): : 2307 - 2324
  • [22] Dual energy subtraction digital radiography - Technical considerations, clinical applications, and imaging pitfalls
    Gilkeson, Robert C.
    Sachs, Peter B.
    JOURNAL OF THORACIC IMAGING, 2006, 21 (04) : 303 - 313
  • [23] Clinical evaluation of noise suppression for low-exposure chest exams with computed radiography
    Couwenhoven, M
    Sehnert, WJ
    Wang, XH
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1314 - 1314
  • [24] Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - A contrast-detail phantom study
    Rong, XJJ
    Shaw, CC
    Liu, XM
    Lemacks, MR
    Thompson, SK
    MEDICAL PHYSICS, 2001, 28 (11) : 2328 - 2335
  • [25] Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system
    Moore, C. S.
    Wood, T. J.
    Saunderson, J. R.
    Beavis, A. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (23): : 9047 - 9058
  • [26] Clinical evaluation of compression ratios using JPEG2000 on computed radiography chest images
    Sung, MM
    Kim, HJ
    Yoo, SK
    Choi, BW
    Nam, JE
    Kim, HS
    Lee, JH
    Yoo, HS
    JOURNAL OF DIGITAL IMAGING, 2002, 15 (02) : 78 - 83
  • [27] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696
  • [28] Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    Sund, P
    Båth, M
    Kheddache, S
    Månsson, LG
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 48 - 58
  • [29] Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    Patrik Sund
    Magnus Båth
    Susanne Kheddache
    Lars Gunnar Månsson
    European Radiology, 2004, 14 : 48 - 58
  • [30] Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages
    Sandborg, Michael
    Tingberg, Anders
    Ullman, Gustaf
    Dance, David R.
    Carlsson, Gudrun Alm
    MEDICAL PHYSICS, 2006, 33 (11) : 4169 - 4175