Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis (July, 10.1007/s00417-021-05271-4, 2021)

被引:0
作者
Desmond, Thomas [1 ,2 ]
Tran, Vincent [2 ]
Maharaj, Monish [3 ,4 ]
Carnt, Nicole [1 ,2 ,5 ,6 ]
White, Andrew [1 ,2 ,5 ]
机构
[1] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Univ New South Wales, Fac Med, Sydney, NSW, Australia
[4] Waikato Hosp, Dept Neurosurg, Hamilton, New Zealand
[5] Westmead Inst Med Res, Sydney, NSW, Australia
[6] UCL, Inst Ophthalmol, London, England
关键词
Anterior segment optical coherence tomography; Glaucoma; Gonioscopy; Narrow angle; OCT; Screening;
D O I
10.1007/s00417-021-05432-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study aims to review the literature that compares the accuracy of Anterior Segment-Optical Coherence Tomography (AS-OCT) against gonioscopy in detecting eyes with angle closure. It is currently unclear how AS-OCT fits into clinical practice for detecting angle closure. This is a systematic review and meta-analysis. Methods: A literature search was performed on Medline, Embase, Scopus and the Cochrane Central Register of Controlled Trials to identify studies that investigated the diagnostic accuracy of AS-OCT in detecting eyes with angle closure as diagnosed by gonioscopy. Eligible studies included in the analysis met stringent inclusion criteria determining the sensitivity and specificity of AS-OCT. Results: The initial search identified 727 studies, of which 23 were included in the final analysis. We found substantial variation in the parameters being studied and methodologies. The sensitivity of AS-OCT ranged from 46 to 100% (median 87%). Twenty-one studies identified parameters that showed sensitivity above 80%. The specificity ranged from 55.3 to 100% (median 84%). Conclusion: AS-OCT demonstrates good sensitivity for detecting angle closure. It may provide an avenue to address high rates of undiagnosed angle closure, such as found in developing Asian countries. However, AS-OCT is not yet able to replace gonioscopy. Clinicians should consider whether the diagnostic accuracy of AS-OCT is acceptable for their specific clinical use before adopting it. More studies are needed to determine the utility of AS-OCT, including longitudinal studies to determine the significance of eyes classified to have closed angles by AS-OCT but open on gonioscopy. © 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
引用
收藏
页码:385 / 385
页数:1
相关论文
共 1 条
[1]   Non-contact tests for identifying people at risk of primary angle closure glaucoma [J].
Jindal, Anish ;
Ctori, Irene ;
Virgili, Gianni ;
Lucenteforte, Ersilia ;
Lawrenson, John G. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2020, (05)