Photoacoustic Detection of Perfluorocarbon Tracers in Air for Application to Leak Detection in Oil-Filled Cables

被引:0
作者
N. Zajarevich
V. Slezak
A. Peuriot
G. Villa
A. Láttero
R. Crivicich
机构
[1] CEILAP-UNIDEF-CITEDEF,
[2] Facultad Regional General Pacheco,undefined
[3] Universidad Tecnológica Nacional (UTN),undefined
来源
International Journal of Thermophysics | 2013年 / 34卷
关键词
Oil-filled cable; Perfluorocarbon; Photoacoustic ; Tracer;
D O I
暂无
中图分类号
学科分类号
摘要
The underground oil-filled cable consists of a hollow copper conductor surrounded by oiled paper which acts as electrical insulation. The oil flows along the conductor and diffuses through it to the insulating paper. A lead sheath is used as the outer retaining wall. As the deterioration of this cover may cause a loss of insulation fluid, its detection is very important since this high voltage and power cable is used in cities even under sidewalks. The method of perfluorocarbon vapor tracers, based on the injection and subsequent detection of these volatile chemical substances in the vicinity of the cable, is one of the most promising methods, so far used in combination with gas chromatography and mass spectrometry. In this study, the possibility of detecting two different tracers, C6F12\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm{C}_{6}\mathrm{F}_{12}$$\end{document} and C7F14\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm{C}_{7}\mathrm{F}_{14}$$\end{document}, by means of resonant photoacoustic spectroscopy is studied. The beam from a tunable amplitude-modulated CO2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm{CO}_{2}$$\end{document} laser goes through an aluminum cell with quarter wave filters at both ends of an open resonator and an electret microphone in its center, attached to the walls. The calibration of the system for either substance diluted in chromatographic air showed a higher sensitivity for C7F14\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm{C}_{7}\mathrm{F}_{14}$$\end{document}, so the experiment was completed checking the behavior of this substance in samples prepared with ambient air in order to analyze the application of the system to field studies.
引用
收藏
页码:1444 / 1450
页数:6
相关论文
共 16 条
[1]  
Ghafurian R(1999)undefined IEEE Trans. Power Deliv. 14 18-undefined
[2]  
Dietz RN(2001)undefined Rev. Sci. Instrum. 72 1937-undefined
[3]  
Rodenbaugh T(1990)undefined Rev. Sci. Instrum. 61 1779-undefined
[4]  
Dominguez J(2006)undefined Water Air Soil Pollut. 170 345-undefined
[5]  
Tai N(1976)undefined Appl. Opt. 15 2480-undefined
[6]  
Miklós A(undefined)undefined undefined undefined undefined-undefined
[7]  
Hess P(undefined)undefined undefined undefined undefined-undefined
[8]  
Bozóki Z(undefined)undefined undefined undefined undefined-undefined
[9]  
Meyer PL(undefined)undefined undefined undefined undefined-undefined
[10]  
Sigrist MW(undefined)undefined undefined undefined undefined-undefined