Development, validation, and application of a novel LC-MS/MS trace analysis method for the simultaneous quantification of seven iodinated X-ray contrast media and three artificial sweeteners in surface, ground, and drinking water

被引:0
作者
Waldemar Ens
Frank Senner
Benjamin Gygax
Götz Schlotterbeck
机构
[1] Industrielle Werke Basel,FHNW University of Applied Sciences and Arts Northwestern Switzerland
[2] School of Life Sciences,undefined
来源
Analytical and Bioanalytical Chemistry | 2014年 / 406卷
关键词
Iodinated X-ray contrast media; Artificial sweeteners; Liquid chromatography-mass spectrometry; Trace analysis; Drinking water production;
D O I
暂无
中图分类号
学科分类号
摘要
A new method for the simultaneous determination of iodated X-ray contrast media (ICM) and artificial sweeteners (AS) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) operated in positive and negative ionization switching mode was developed. The method was validated for surface, ground, and drinking water samples. In order to gain higher sensitivities, a 10-fold sample enrichment step using a Genevac EZ-2 plus centrifugal vacuum evaporator that provided excellent recoveries (90 ± 6 %) was selected for sample preparation. Limits of quantification below 10 ng/L were obtained for all compounds. Furthermore, sample preparation recoveries and matrix effects were investigated thoroughly for all matrix types. Considerable matrix effects were observed in surface water and could be compensated by the use of four stable isotope-labeled internal standards. Due to their persistence, fractions of diatrizoic acid, iopamidol, and acesulfame could pass the whole drinking water production process and were observed also in drinking water. To monitor the fate and occurrence of these compounds, the validated method was applied to samples from different stages of the drinking water production process of the Industrial Works of Basel (IWB). Diatrizoic acid was found as the most persistent compound which was eliminated by just 40 % during the whole drinking water treatment process, followed by iopamidol (80 % elimination) and acesulfame (85 % elimination). All other compounds were completely restrained and/or degraded by the soil and thus were not detected in groundwater. Additionally, a direct injection method without sample preparation achieving 3–20 ng/L limits of quantification was compared to the developed method.
引用
收藏
页码:2789 / 2798
页数:9
相关论文
共 78 条
[1]  
Christiansen C(2005)undefined Toxicology 209 185-187
[2]  
Pérez S(2007)undefined Anal Bioanal Chem 387 1235-1246
[3]  
Barceló D(2009)undefined Anal Bioanal Chem 394 1585-1594
[4]  
Scheurer M(2008)undefined J Chromatogr A 1213 200-208
[5]  
Brauch H-J(2012)undefined Anal Bioanal Chem 403 2503-2518
[6]  
Lange FT(2012)undefined Anal Methods 4 3057-3070
[7]  
Busetti F(2012)undefined Sci Total Environ 430 8-19
[8]  
Linge KL(2000)undefined Fresenius J Anal Chem 366 835-841
[9]  
Blythe JW(2007)undefined Water Res 41 1580-1586
[10]  
Heitz A(2001)undefined J Chromatogr A 938 199-210