Numerical evaluation and experimental validation of cross-flow microfiltration device design

被引:0
|
作者
Marisel De Jesús Vega
Joseph Wakim
Nese Orbey
Carol Barry
机构
[1] University of Massachusetts Lowell,Department of Chemical Engineering
[2] University of Massachusetts Lowell,Department of Plastics Engineering
来源
Biomedical Microdevices | 2019年 / 21卷
关键词
Cross-flow microfiltration; Microfluidic device; COMSOL simulations; Optimization; Testing with microspheres;
D O I
暂无
中图分类号
学科分类号
摘要
This research presents a comprehensive analysis of the design and validation of a cross-flow microfiltration device for separation of microspheres based on size. Simulation results showed that pillar size, pillar shape, incorporation of back-flow preventers, and rounding of pillar layouts affected flow patterns in a cross-flow microfiltration device. Simulation results suggest that larger pillar sizes reduce filtration capacity by decreasing the density of microfiltration gaps in the device. Therefore, 10 μm rather than 20 μm diameter pillars were incorporated in the device. Fluid flow was not greatly affected when comparing circular, octagonal, and hexagonal pillars. However, side-channel fluid velocities decreased when using triangular and square pillars. The lengths of back-flow prevention walls were optimized to completely prevent back flow without inhibiting filtration ability. A trade-off was observed in the designs of the pillar layouts; while rounding the pillars layout in the channels bends eliminated stagnation areas, the design also decreased side-channel fluid velocity compared to the right-angle layout. Experimental separation efficiency was tested using polydimethylsiloxane (PDMS) and silicon microfluidic devices with microspheres simulating white and red blood cells. Efficiencies for separation of small microspheres to the side channels ranged from 73 to 75%. The silicon devices retained the large microspheres in the main channel with efficiencies between 95 and 100%, but these efficiencies were lower with PDMS devices and were affected by sphere concentration. Additionally, PDMS devices resulted in greater agglomeration of spheres when compared to silicon devices. PDMS devices, however, were easier and less expensive to fabricate.
引用
收藏
相关论文
共 50 条
  • [21] CHOOSING BETWEEN CENTRIFUGATION AND CROSS-FLOW MICROFILTRATION
    MACKAY, D
    SALUSBURY, T
    CHEMICAL ENGINEER-LONDON, 1988, (447): : 45 - 50
  • [22] CROSS-FLOW MICROFILTRATION OF ANIMAL-CELLS
    MAIORELLA, B
    DORIN, G
    CARION, A
    HARANO, D
    BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (02) : 121 - 126
  • [23] CROSS-FLOW MICROFILTRATION OF BACTERIAL-CELLS
    SHIMIZU, Y
    SHIMODERA, K
    WATANABE, A
    JOURNAL OF FERMENTATION AND BIOENGINEERING, 1993, 76 (06): : 493 - 500
  • [24] The use of cross-flow microfiltration in purification of liposomes
    Hwang, KJ
    Chang, YC
    SEPARATION SCIENCE AND TECHNOLOGY, 2004, 39 (11) : 2557 - 2576
  • [25] Modelling of critical flux in cross-flow microfiltration
    Kwon, DY
    Vigneswaran, S
    ENVIRONMENTAL HYDRAULICS, 1999, : 765 - 770
  • [26] Modeling of fouling in cross-flow microfiltration of suspensions
    Weeranoppanant, Nopphon
    Amar, Levy I.
    Tong, Evelyn
    Faria, Monica
    Hill, Michael I.
    Leonard, Edward F.
    AICHE JOURNAL, 2019, 65 (01) : 207 - 213
  • [27] VISUALIZATION OF CAKE FORMATION IN CROSS-FLOW MICROFILTRATION
    WAKEMAN, RJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1994, 72 (A4): : 530 - 540
  • [28] Clarification of tomato juice by cross-flow microfiltration
    Razi, Behnaz
    Aroujalian, Abdolreza
    Raisi, Ahmadreza
    Fathizadeh, Mahdi
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2011, 46 (01): : 138 - 145
  • [29] Cross-flow microfiltration of submicron microbial suspension
    Hwang, KJ
    Yu, YH
    Lu, WM
    JOURNAL OF MEMBRANE SCIENCE, 2001, 194 (02) : 229 - 243
  • [30] MECHANISMS AND CONTROL OF FOULING IN CROSS-FLOW MICROFILTRATION
    WENTEN, IG
    FILTRATION & SEPARATION, 1995, 32 (03): : 252 - 253