Construction of calibration-locking databases for rapid and reliable drug screening by gas chromatography-mass spectrometry

被引:0
作者
Keiko Kudo
Tomomi Ishida
Wakako Hikiji
Makiko Hayashida
Kyoko Uekusa
Yosuke Usumoto
Akiko Tsuji
Noriaki Ikeda
机构
[1] Kyushu University,Department of Forensic Pathology and Sciences, Graduate School of Medical Sciences
[2] Nippon Medical School,Department of Legal Medicine
来源
Forensic Toxicology | 2009年 / 27卷
关键词
Calibration-locking database; Systematic toxicological analysis; Enhanced polymer column; GC-MS; Acetylation; NAGINATA;
D O I
暂无
中图分类号
学科分类号
摘要
Unique calibration-locking databases were constructed for rapid and semiquantitative drug screening by gas chromatography-mass spectrometry (GCMS). In addition to the free-drug database of 127 drugs, a drug database with acetylating reagents was constructed to increase the number of detectable compounds in the analysis by GC-MS; 156 drugs, including 30 drugs of abuse, 42 hypnotics and their metabolites, 18 antipsychotic drugs, 15 antidepressants, and 12 antipyretic analgesic agents, were registered with parameters, such as the mass spectrum, retention time, qualifier ion/target ion percentage, and calibration curve using the novel GC-MS software NAGINATA. Diazepam-d5 was used as internal standard for construction of each calibration curve in the range of 0.01–5.0 μg/ml for most drugs. We examined the applicability of the constructed database to analyzing whole blood samples spiked with 40 drugs most commonly encountered in toxicological cases in Japan. The drugs in blood were extracted using enhanced polymer columns (Focus), subjected to GC-MS after incubation with acetylating reagents, and screened by the drug database. Among the 40 drugs examined, 38 and 30 drugs were successfully identifi ed at the level of 1 and 0.1 μg/ml, respectively, without using standard compounds. The time required for data analysis was less than 1 min, and semiquantitative data were also obtained simultaneously. Because new drugs and metabolites can easily be added to the databases, we can recommend them as useful tools in clinical and forensic toxicological screening.
引用
收藏
页码:21 / 31
页数:10
相关论文
共 49 条
[1]  
Rasanen I.(2003)Precise gas chromatography with retention time locking in comprehensive toxicological screening for drugs in blood J Chromatogr B 788 243-250
[2]  
Kontinen I.(2007)Toxicological screening in urine: comparison of two automated HPLC screening systems, toxicological identification system (TOX.I.S.*) versus REMEDI™-HS J Anal Toxicol 31 321-327
[3]  
Nokua J.(2004)Systematic toxicological analysis by high-performance liquid chromatography with diode array detection (HPLC-DAD) Clin Chem Lab Med 42 1325-1340
[4]  
Ojanperä I.(2003)Toxicological screening with formula-based metabolite identification by liquid chromatography/time-of-flight mass spectrometry Anal Chem 75 5710-5718
[5]  
Vuori E.(2006)Hyphenated mass spectrometric techniques—indispensable tools in clinical and forensic toxicology and in doping control J Mass Spectrom 41 1399-1413
[6]  
Schönberg L.(1999)Systematic toxicological analysis procedures for acidic drugs and/or metabolites relevant to clinical and forensic toxicology and/or doping control J Chromatogr B 733 3-25
[7]  
Grobosch T.(1996)The advantage of dual-column approach and retention indices combined with refined reporting in gas chromatographic drug screening J High Resol Chromatogr 19 313-321
[8]  
Lampe D.(2005)Novel gas chromatography-mass spectrometry database for automatic identification and quantification of micropollutants J Chromatogr A 1089 219-226
[9]  
Kloft C.(2007)Rapid diagnosis of drug intoxication using novel NAGINATA™ gas chromatography/mass spectrometry software Rapid Commun Mass Spectrom 21 3129-3138
[10]  
Pragst F.(2007)Simultaneous determination of 13 amphetamine related drugs in human whole blood using an enhanced polymer column and gas chromatography-mass spectrometry J Chromatogr B 855 115-120