A method for the analysis and classification of historic masonry

被引:0
作者
Antonio Borri
Marco Corradi
Giulio Castori
Alessandro De Maria
机构
[1] University of Perugia,Department of Engineering
[2] Northumbria University,Department of Mechanical and Construction Engineering
[3] Servizio Controllo Costruzioni e Protezione Civile,undefined
[4] Provincia di Perugia,undefined
来源
Bulletin of Earthquake Engineering | 2015年 / 13卷
关键词
Historic masonry; Seismic vulnerability; In-site testing; Mechanical properties;
D O I
暂无
中图分类号
学科分类号
摘要
It is known that the mechanical behavior of masonry material depends on many factors, such as compressive or shear strength of components (mortar and blocks), blocks shape, volumetric ratio between components and wall texture, that is the result of applying a series of construction devices which form the “rule of the art”. Taking into account the complexity of the problem due to the great number of variables, a fair assessment of the load carrying capacity of masonries can be made only with in situ test. Being in situ test a semi-destructive methods, not always viable, a numerical estimate of the mechanical parameters of the walls can be made on the basis of a qualitative criteria evaluation. The method here proposed, called Masonry Quality Index method, consists in evaluating the presence, the partial presence, or the absence of certain parameters that define the “rule of the art”, namely a set of construction devices that, if executed during the construction of a wall, provides a good behavior and ensure the compactness and the monolithicity.
引用
收藏
页码:2647 / 2665
页数:18
相关论文
共 35 条
[1]  
Binda L(2000)Investigation procedures for the diagnosis of historic masonries J Constr Build Mater 14 199-233
[2]  
Saisi A(2011)Shear behavior of unreinforced and reinforced masonry panels subjected to in-situ diagonal compression tests Constr Build Mater 25 4403-4414
[3]  
Tiraboschi C(1993)In-situ determination of the strength properties of masonry walls by destructive shear and compression tests Mason Int 7 87-96
[4]  
Borri A(2003)Experimental study on the determination of strength of masonry walls J Constr Build Mater 17 325-337
[5]  
Castori G(2014)Shear strengthening of wall panels through jacketing with cement mortar reinforced by GFRP grids Compos B 64 33-42
[6]  
Corradi M(2011)Assessment and analysis of damage in L’Aquila historic city centre after 6th April 2009 Bull Earthq Eng 9 81-104
[7]  
Speranzini E(2004)Seismic vulnerability of ancient churches: II. Statistical analysis of surveyed data and methods for risk analysis Earthq Spectra 20 395-412
[8]  
Chiostrini S(2011)Analysis of masonry structures without box behavior Int J Archit Herit Conserv Anal Restor 5 369-382
[9]  
Vignoli A(2014)A framework for the seismic assessment of existing masonry buildings accounting for different sources of uncertainty Earthq Eng Struct Dyn 43 1045-1066
[10]  
Corradi M(2013)The Medina of Chefchaouen (Morocco): a survey on morphological and mechanical features of the masonries Constr Build Mater 47 465-479