A soft, scalable and adaptable multi-contact cuff electrode for targeted peripheral nerve modulation

被引:8
|
作者
Paggi V. [1 ]
Fallegger F. [1 ]
Serex L. [2 ]
Rizzo O. [1 ,3 ]
Galan K. [1 ]
Giannotti A. [4 ]
Furfaro I. [1 ]
Zinno C. [4 ]
Bernini F. [4 ]
Micera S. [3 ,4 ]
Lacour S.P. [1 ]
机构
[1] Laboratory for Soft Bioelectronic Interfaces, Neuro-X Institute, Ecole Polytechnique Fédérale de Lausanne (EPFL), Geneva
[2] Neurosoft Bioelectronics SA, Geneva
[3] Bertarelli Foundation Chair in Translational NeuroEngineering, Neuro-X Institute, École Polytechnique Fédérale de Lausanne (EPFL), Geneva
[4] The BioRobotics Institute and Department of Excellence in Robotics and AI, Scuola Superiore Sant’Anna, Pisa
关键词
Cuff electrode; Peripheral nerve interfaces; Selective stimulation; Soft bioelectronics;
D O I
10.1186/s42234-023-00137-y
中图分类号
学科分类号
摘要
Background: Cuff electrodes target various nerves throughout the body, providing neuromodulation therapies for motor, sensory, or autonomic disorders. However, when using standard, thick silicone cuffs, fabricated in discrete circular sizes, complications may arise, namely cuff displacement or nerve compression, due to a poor adaptability to variable nerve shapes and sizes encountered in vivo. Improvements in cuff design, materials, closing mechanism and surgical approach are necessary to overcome these issues. Methods: In this work, we propose a microfabricated multi-channel silicone-based soft cuff electrode with a novel easy-to-implant and size-adaptable design and evaluate a number of essential features such as nerve-cuff contact, nerve compression, cuff locking stability, long-term integration and stimulation selectivity. We also compared performance to that of standard fixed-size cuffs. Results: The belt-like cuff made of 150 μm thick silicone membranes provides a stable and pressure-free conformal contact, independently of nerve size variability, combined with a straightforward implantation procedure. The adaptable design and use of soft materials lead to limited scarring and demyelination after 6-week implantation. In addition, multi-contact designs, ranging from 6 to 16 electrodes, allow for selective stimulation in models of rat and pig sciatic nerve, achieving targeted activation of up to 5 hindlimb muscles. Conclusion: These results suggest a promising alternative to classic fixed-diameter cuffs and may facilitate the adoption of soft, adaptable cuffs in clinical settings. © The Author(s) 2024.
引用
收藏
相关论文
共 13 条
  • [1] Nerve stimulation with a multi-contact cuff electrode: Validation of model predictions
    Deurloo, KEI
    Holsheimer, J
    Bergveld, P
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (04) : 349 - 359
  • [2] Selective stimulation of the hypoglossal nerve with a multi-contact cuff electrode
    Yoo, PB
    Durand, DM
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1309 - 1312
  • [3] Assessment on selectivity of multi-contact cuff electrode for recording peripheral nerve signals using Fitzhugh-Nagumo model of nerve excitation
    Taghipour-Farshi, Hamed
    Frounchi, Javad
    Ahmadiasl, Nasser
    Shahabi, Parviz
    Salekzamani, Yaghoub
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2016, 29 (04) : 749 - 756
  • [4] Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees
    Tan, Daniel W.
    Schiefer, Matthew A.
    Keith, Michael W.
    Anderson, J. Robert
    Tyler, Dustin J.
    JOURNAL OF NEURAL ENGINEERING, 2015, 12 (02)
  • [5] Influence of Anatomical Detail and Tissue Conductivity Variations in Simulations of Multi-Contact Nerve Cuff Recordings
    Garai, Purbasha
    Koh, Ryan G. L.
    Schuettler, Martin
    Stieglitz, Thomas
    Zariffa, Jose
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (09) : 1653 - 1662
  • [6] Interleaved Multi-Contact Peripheral Nerve Stimulation to Enhance Reproduction of Tactile Sensation: A Computational Modeling Study
    Tebcherani, Tanya M.
    Loparo, Kenneth A.
    Kaffashi, Farhad
    Tyler, Dustin J.
    Graczyk, Emily L.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 2302 - 2313
  • [7] A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
    Yu, Huaiqiang
    Xiong, Wenjie
    Zhang, Hongze
    Wang, Wei
    Li, Zhihong
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2014, 23 (05) : 1025 - 1035
  • [8] A Soft and Stretchable Multielectrode Cuff for Selective Peripheral Nerve Stimulation
    Lienemann, Samuel
    Donahue, Mary J.
    Zotterman, Johan
    Farnebo, Simon
    Tybrandt, Klas
    ADVANCED MATERIALS TECHNOLOGIES, 2023, 8 (06)
  • [9] Self-Closed Parylene Cuff Electrode for Peripheral Nerve Recording
    Kang, Xiaoyang
    Liu, Jing-Quan
    Tian, Hongchang
    Yang, Bin
    Nuli, Yanna
    Yang, Chunsheng
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2015, 24 (02) : 319 - 332
  • [10] Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
    Brill, N. A.
    Naufel, S. N.
    Polasek, K.
    Ethier, C.
    Cheesborough, J.
    Agnew, S.
    Miller, L. E.
    Tyler, D. J.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (03)