Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor

被引:17
作者
Ishikura R. [1 ]
Ando K. [1 ]
Nagami Y. [1 ]
Yamamoto S. [1 ]
Miura K. [1 ]
Pande A.R. [1 ]
Yamano T. [1 ]
Hirota S. [1 ]
Nakao N. [1 ]
机构
[1] Department of Radiology, Hyogo College of Medicine, Nishinomiya, Hyogo 663-8501
来源
Radiation Medicine | 2006年 / 24卷 / 5期
关键词
Cone-beam CT; Flat panel detector; Interventional radiology; Skull bone tumor;
D O I
10.1007/s11604-006-0038-x
中图分类号
学科分类号
摘要
A cone-beam lowers the X-ray exposure level and the contrast material dose used compared to those for the conventional angiography-computed tomography (angio-CT) technique. Herein we present a patient with a metastatic skull base bone tumor in which the subtraction image of cone-beam CT with a flat panel detector was useful for evaluating the vascular supply during superselective intraarterial chemotherapy. Although the image quality of cone-beam CT is poorer than that of conventional angio-CT, the cone-beam CT system is sufficient for clinical use. © Japan Radiological Society 2006.
引用
收藏
页码:384 / 387
页数:3
相关论文
共 13 条
[1]  
Korogi Y., Hirai T., Nishimura R., Hamatake S., Sakamoto Y., Murakami R., Et al., Superselective intraarterial infusion of cisplatin for squamous cell carcinoma of the mouth: Preliminary clinical experience, AJR Am J Roentgenol, 165, pp. 1269-1272, (1995)
[2]  
Hirai T., Korogi Y., Hamatake S., Nishimura R., Baba Y., Takahashi M., Et al., Stages III and IV squamous cell carcinoma of the mouth: Three-year experience with superselective intraarterial chemotherapy using cisplatin prior to definitive treatment, Cardiovasc Intervent Radiol, 22, pp. 201-205, (1999)
[3]  
Robbins K.T., Vicario D., Seagren S., Weisman R., Pellitteri P., Kerber C., Et al., A targeted supradose cisplatin chemoradiation protocol for advanced head and neck cancer, Am J Surg, 168, pp. 419-422, (1994)
[4]  
Kerber C.W., Wong W.H., Howell S.B., Hanchett K., Robbins K.T., An organ-preserving selective arterial chemotherapy strategy for head and neck cancer, AJNR Am J Neuroradiol, 19, pp. 935-941, (1998)
[5]  
Hirai T., Korogi Y., Ono K., Uemura S., Yamashita Y., Preoperative embolization for meningeal tumors: Evaluation of vascular supply with angio-CT, AJNR Am J Neuroradiol, 25, pp. 74-76, (2004)
[6]  
Feldkamp L.A., Davis L.C., Kress J.W., Practical cone-beam algorithm, J Opt Soc Am, 1, pp. 612-619, (1984)
[7]  
Suzuki K., Ikeda S., Ueda K., Nakamura T., Okabe M., Kadomura T., Et al., Development of angiography system with cone-beam reconstruction using large-area flat panel detector, Med Imaging, 5368, pp. 488-498, (2004)
[8]  
Baba R., Konno Y., Ueda K., Ikeda S., Comparison of flat-panel detector and image- intensifier detector for cone-beam CT, Comput Med Imaging Graph, 26, pp. 153-158, (2002)
[9]  
Endo M., Tsunoo T., Kandatsu S., Tanada S., Aradate H., Saito Y., Four-dimensional computed tomography (4D CT): Concepts and preliminary development, Radiat Med, 21, pp. 17-22, (2003)
[10]  
Baba R., Ueda K., Okabe M., Using a flat-panel detector in high resolution cone beam CT for dental imaging, Dentomaxillofac Radiol, 33, pp. 285-290, (2004)