Comparison of Suomi-NPP OMPS total column ozone with Brewer and Dobson spectrophotometers measurements

被引:0
|
作者
Kaixu Bai
Chaoshun Liu
Runhe Shi
Wei Gao
机构
[1] East China Normal University,Key Laboratory of Geographic Information Science (Ministry of Education)
[2] East China Normal University,Joint Laboratory for Environmental Remote Sensing and Data Assimilation
[3] Colorado State University,Department of Ecosystem Science and Sustainability
来源
Frontiers of Earth Science | 2015年 / 9卷
关键词
ozone mapping and profiler suite; total column ozone; Brewer; Dobson;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this study is to evaluate the accuracy of the daily nadir total column ozone products derived from the nadir mapper instrument on the Ozone Mapping and Profiler Suite (OMPS) flying onboard the Suomi National Polar-orbiting Partnership satellite (S-NPP) launched as a part of the Joint Polar Satellite System (JPSS) program between NOAA and NASA. Since NOAA is already operationally processing OMPS nadir total ozone products, evaluations were made in this study on the total column ozone research products generated by NASA’s science team, utilizing the latest version of their Backscatter Ultraviolet (BUV) retrieval algorithms, to provide insight into the performance of the operation system. Comparisons were made with globally distributed ground-based Brewer and Dobson spectrophotometer total column ozone measurements. Linear regressions show fair agreement between OMPS and ground-based total column ozone measurements with a root-mean-square error (RMSE) of approximately 3% (10 DU). The comparison results indicate that the OMPS total column ozone data are 0.59% higher than the Brewer measurements with a standard deviation of 2.82% while 1.09% higher than the Dobson measurements with a standard deviation of 3.27%. Additionally, the variability of relative differences between OMPS and ground total column ozone were analyzed as a function of latitude, time, viewing geometry, and total column ozone value. Results show a 2% bias over most latitudes and viewing conditions when total column ozone value varies between 220 DU and 450 DU.
引用
收藏
页码:369 / 380
页数:11
相关论文
共 33 条
  • [1] Comparison of Suomi-NPP OMPS total column ozone with Brewer and Dobson spectrophotometers measurements
    Bai, Kaixu
    Liu, Chaoshun
    Shi, Runhe
    Gao, Wei
    FRONTIERS OF EARTH SCIENCE, 2015, 9 (03) : 369 - 380
  • [2] Evaluation of the performance of Suomi-NPP OMPS nadir mapper products using station measurements and OMI data
    Zhang, Yiwei
    Mao, Zhihua
    Tao, Bangyi
    Bai, Kaixu
    Chen, Peng
    Shi, Liangliang
    Huang, Haiqing
    Wang, Zheng
    JOURNAL OF APPLIED REMOTE SENSING, 2018, 12 (04):
  • [3] A comparison of 40 years of SBUV measurements of column ozone with data from the Dobson/Brewer network
    Labow, Gordon J.
    McPeters, Richard D.
    Bhartia, Pawan K.
    Kramarova, Natalya
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2013, 118 (13) : 7370 - 7378
  • [4] Quality assessment of Dobson spectrophotometers for ozone column measurements before and after automation at Arosa and Davos
    Stubi, Rene
    Schill, Herbert
    Barras, Eliane Maillard
    Klausen, Jorg
    Haefele, Alexander
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (06) : 4203 - 4217
  • [5] A fully automated Dobson sun spectrophotometer for total column ozone and Umkehr measurements
    Stubi, Rene
    Schill, Herbert
    Klausen, Jorg
    Barras, Eliane Maillard
    Haefele, Alexander
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (08) : 5757 - 5769
  • [6] Validation of total ozone column derived from OMPS using ground-based spectroradiometer measurements
    Chen, Zuoqi
    Yu, Bailang
    Huang, Yan
    Hu, Yingjie
    Lin, Hao
    Wu, Jianping
    REMOTE SENSING LETTERS, 2013, 4 (10) : 937 - 945
  • [7] Evaluation of Total Ozone Column from Multiple Satellite Measurements in the Antarctic Using the Brewer Spectrophotometer
    Kim, Songkang
    Park, Sang-Jong
    Lee, Hana
    Ahn, Dha Hyun
    Jung, Yeonjin
    Choi, Taejin
    Lee, Bang Yong
    Kim, Seong-Joong
    Koo, Ja-Ho
    REMOTE SENSING, 2021, 13 (08)
  • [8] Comparison of Brewer ultraviolet irradiance measurements with total ozone mapping spectrometer satellite retrievals
    Fioletov, VE
    Kerr, JB
    Wardle, DI
    Krotkov, N
    Herman, JR
    OPTICAL ENGINEERING, 2002, 41 (12) : 3051 - 3061
  • [9] On the compatibility of Brewer total column ozone measurements in two adjacent valleys (Arosa and Davos) in the Swiss Alps
    Stubi, Rene
    Schill, Herbert
    Klausen, Jorg
    Vuilleumier, Laurent
    Grobner, Julian
    Egli, Luca
    Ruffieux, Dominique
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (11) : 4479 - 4490
  • [10] Reproducibility of total ozone column monitoring by the Arosa Brewer spectrophotometer triad
    Stubi, R.
    Schill, H.
    Klausen, J.
    Vuilleumier, L.
    Ruffieux, D.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2017, 122 (08) : 4735 - 4745