A hydrogen peroxide biosensor based on direct electron transfer from hemoglobin to an electrode modified with Nafion and activated nanocarbon

被引:0
作者
Jie Song
JiMing Xu
PuSu Zhao
LuDe Lu
JianChun Bao
机构
[1] Nanjing University of Science and Technology,Materials Chemistry Laboratory
[2] Huaiyin Normal University,Jiangsu Key Laboratory for Chemistry of Low
来源
Microchimica Acta | 2011年 / 172卷
关键词
Hydrogen peroxide biosensor; AC/NF composite film; Hemoglobin; Direct electron transfer;
D O I
暂无
中图分类号
学科分类号
摘要
A biosensor for hydrogen peroxide (HP) was developed by immobilizing hemoglobin on a glassy carbon electrode modified with activated carbon nanoparticles/Nafion. The characteristics of the sensor were studied by UV–vis spectroscopy and electrochemical methods. The immobilized Hb retained its native secondary structure, undergoes direct electron transfer (with a heterogeneous rate constant of 3.37 ± 0.5 s−1), and displays excellent bioelectrocatalytic activity to the reduction of HP. Under the optimal conditions, its amperometric response varies linearly with the concentration of HP in the range from 0.9 μM to 17 μM. The detection limit is 0.4 μM (at S/N = 3). Due to the commercial availability and low cost of activated carbon nanoparticles, it can be considered as a useful supporting material for construction of other third-generation biosensors.
引用
收藏
页码:117 / 123
页数:6
相关论文
共 137 条
[11]  
Satowa T(2009)Nonenzymatic hydrogen peroxide sensor based on a polyaniline-single walled carbon nanotubes composite in a room temperature ionic liquid Microchim Acta 166 215-220
[12]  
Imakawa K(1996)Catalytic reduction of myoglobin and hemoglobin at chemically modified electrodes containing methylene blue Sensor Actuat B-Chem 33 50-54
[13]  
Nagaoka K(2003)Direct electrochemical behavior of hemoglobin at surface of Au@Fe3O4 magnetic nanoparticles Biosens Bioelectron 18 211-215
[14]  
Hong J(2006)Electron transfer principles in amperometric biosensors: direct electron transfer between enzymes and electrode surface J Anal Chem 78 5538-5542
[15]  
Dai Z(2001)Novel carbon materials in biosensor systems J Anal Chem 73 2850-2854
[16]  
Liu S(2010)Carbon nanofiber-based glucose biosensor Microchim Acta 169 181-186
[17]  
Dai ZH(2005)Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP Sephadex membrane Langmuir 21 9000-9006
[18]  
Chen HY(2007)Direct electrochemistry and electrocatalysis of hydrogen peroxide using hemoglobin immobilized in hollow zirconium dioxide spheres and sodium alginate films Bioelectrochemistry 71 135-141
[19]  
Ju HX(2008)Molecular films of water-miscible ionic liquids formed on glassy carbon electrodes: characterization and electrochemical applications Talanta 75 1348-1355
[20]  
Chen Y(2009)Direct electrochemistry and electrocatalysis of hemoglobin entrapped in semi-interpenetrating polymer network hydrogel based on polyacrylamide and chitosan Sensors 9 8547-8561