PtNPs-GNPs-MWCNTs-β-CD nanocomposite modified glassy carbon electrode for sensitive electrochemical detection of folic acid

被引:0
作者
Meng-Meng Yuan
Jiao Zou
Zhao-Ning Huang
Dong-Ming Peng
Jin-Gang Yu
机构
[1] Central South University,College of Chemistry and Chemical Engineering
[2] Hunan University of Chinese Medicine,School of Pharmacy
来源
Analytical and Bioanalytical Chemistry | 2020年 / 412卷
关键词
Cyclic voltammetry; Electrochemical detection; Folic acid; PtNPs-GNPs-MWCNTs-β-CD;
D O I
暂无
中图分类号
学科分类号
摘要
A novel electrochemical sensor, platinum nanoparticles/graphene nanoplatelets/multi-walled carbon nanotubes/β-cyclodextrin composite (PtNPs-GNPs-MWCNTs-β-CD) modified carbon glass electrode (GCE), was fabricated and used for the sensitive detection of folic acid (FA). The PtNPs-GNPs-MWCNTs-β-CD nanocomposite was easily prepared with an ultrasound-assisted assembly method, and it was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The electrochemical behavior of FA at PtNPs-GNPs-MWCNTs-β-CD/GCE was investigated in detail. Some key experimental parameters such as pH, amount of PtNPs-GNPs-MWCNTs-β-CD composite, and scan rate were optimized. A good linear relationship (R2 = 0.9942) between peak current of cyclic voltammetry (CV) and FA concentration in the range 0.02–0.50 mmol L−1 was observed at PtNPs-GNPs-MWCNTs-β-CD/GCE. The detection limit was 0.48 μmol L−1 (signal-to-noise ratio = 3). A recovery of 97.55–102.96% was obtained for the determination of FA in FA pills (containing 0.4 mg FA per pill) at PtNPs-GNPs-MWCNTs-β-CD/GCE, indicating that the modified electrode possessed relatively high sensitivity and stability for the determination of FA in real samples.
引用
收藏
页码:2551 / 2564
页数:13
相关论文
共 297 条
  • [31] Bertuzzi T(2020)Nanostructured silver doped TiO Ecotox Environ Saf 190 110123-2271
  • [32] Rastelli S(2015)/CNTs hybrid as an efficient electrochemical sensor for detection of anti-inflammatory drug, cetirizine Anal Bioanal Chem 407 8911-3968
  • [33] Mulazzi A(2019)A new electrochemical aptasensor based on MWCNT-SiO Ecotox Environ Saf 172 167-2471
  • [34] Rossi F(2006)@Au core-shell nanocomposite for ultrasensitive detection of bisphenol A Anal Chem 78 2268-1134
  • [35] Cao Y(2010)A graphene-based electrochemical sensor for sensitive detection of paracetamol ACS Nano 4 3959-13
  • [36] Griffith B(2006)Hydrothermal fabrication of novel three-dimensional graphene oxide-pentaerythritol composites with abundant oxygen-containing groups as efficient adsorbents Chem Mater 18 2468-2956
  • [37] Bhomkar P(2011)Highly sensitive electrochemical sensor using a MWCNTs/GNPs-modified electrode for lead (II) detection based on Pb Electrochem Commun 13 1131-2689
  • [38] Wishart DS(2018)-induced G-rich DNA conformation J Ind Eng Chem 68 6-4464
  • [39] McDermott MT(2009)One-step synthesis of reduced graphene oxide sheathed zinc oxide nanoclusters for the trace level detection of bisphenol A in tissue papers Chem Mater 21 2950-533
  • [40] Hoyos-Arbeláez J(2020)A sensitive non-enzymatic electrochemical sensor based on acicular manganese dioxide modified graphene nanosheets composite for hydrogen peroxide detection Mater Sci Eng A 769 138484-33