PtNPs-GNPs-MWCNTs-β-CD nanocomposite modified glassy carbon electrode for sensitive electrochemical detection of folic acid

被引:0
作者
Meng-Meng Yuan
Jiao Zou
Zhao-Ning Huang
Dong-Ming Peng
Jin-Gang Yu
机构
[1] Central South University,College of Chemistry and Chemical Engineering
[2] Hunan University of Chinese Medicine,School of Pharmacy
来源
Analytical and Bioanalytical Chemistry | 2020年 / 412卷
关键词
Cyclic voltammetry; Electrochemical detection; Folic acid; PtNPs-GNPs-MWCNTs-β-CD;
D O I
暂无
中图分类号
学科分类号
摘要
A novel electrochemical sensor, platinum nanoparticles/graphene nanoplatelets/multi-walled carbon nanotubes/β-cyclodextrin composite (PtNPs-GNPs-MWCNTs-β-CD) modified carbon glass electrode (GCE), was fabricated and used for the sensitive detection of folic acid (FA). The PtNPs-GNPs-MWCNTs-β-CD nanocomposite was easily prepared with an ultrasound-assisted assembly method, and it was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The electrochemical behavior of FA at PtNPs-GNPs-MWCNTs-β-CD/GCE was investigated in detail. Some key experimental parameters such as pH, amount of PtNPs-GNPs-MWCNTs-β-CD composite, and scan rate were optimized. A good linear relationship (R2 = 0.9942) between peak current of cyclic voltammetry (CV) and FA concentration in the range 0.02–0.50 mmol L−1 was observed at PtNPs-GNPs-MWCNTs-β-CD/GCE. The detection limit was 0.48 μmol L−1 (signal-to-noise ratio = 3). A recovery of 97.55–102.96% was obtained for the determination of FA in FA pills (containing 0.4 mg FA per pill) at PtNPs-GNPs-MWCNTs-β-CD/GCE, indicating that the modified electrode possessed relatively high sensitivity and stability for the determination of FA in real samples.
引用
收藏
页码:2551 / 2564
页数:13
相关论文
共 297 条
  • [1] Herbert V(1965)Folic acid Annu Rev Med 16 359-370
  • [2] Catala GN(2019)Folate, genomic stability and colon cancer: the use of single cell gel electrophoresis in assessing the impact of folate in vitro, in vivo and in human biomonitoring Mutat Res 843 73-80
  • [3] Bestwick CS(2019)High doses of folic acid in the periconceptional period and risk of low weight for gestational age at birth in a population based cohort study Eur J Nutr 58 241-251
  • [4] Russell WR(2018)Simple coupled ultrahigh performance liquid chromatography and ion chromatography technique for simultaneous determination of folic acid and inorganic anions in folic acid tablets Food Chem 239 62-67
  • [5] Tortora K(2017)Nitrogen-doped carbon quantum dots as a fluorescence probe combined with magnetic solid-phase extraction purification for analysis of folic acid in human serum Anal Bioanal Chem 409 7063-7075
  • [6] Giovannelli L(2019)LC-MS/MS determination of mono-glutamate folates and folic acid in beer Food Anal Method 12 722-728
  • [7] Moyer MP(2018)Functionalized gold nanoparticle-enhanced competitive assay for sensitive small-molecule metabolite detection using surface plasmon resonance Analyst 143 289-296
  • [8] Lendoiro E(2017)Electrochemical methods as a tool for determining the antioxidant capacity of food and beverages: a review Food Chem 221 1371-1381
  • [9] Duthie SJ(2018)Free-standing and flexible MoS Electroanal 30 810-818
  • [10] Navarrete-Muñoz EM(2018)/rGO paper electrode for amperometric detection of folic acid Int J Electrochem Sci 13 11702-11719