High-performance polyethylene dissolved oxygen sensor with a petallike surface

被引:0
作者
Wei Zhao
Honglin Zhang
Li Xiao
Sai Chen
Yongpan Cheng
Hongbo Xu
Ke Zhang
Jiupeng Zhao
Yao Li
机构
[1] Harbin Institute of Technology,MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering
[2] North China Electric Power University,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy
[3] Harbin Institute of Technology,Center for Composite Materials
来源
Colloid and Polymer Science | 2021年 / 299卷
关键词
Dissolved oxygen; Platinum octaethylporphyrin; Porous polyethylene film; Stern–Volmer equation;
D O I
暂无
中图分类号
学科分类号
摘要
Dissolved oxygen (DO) level is of capital importance in the field of environmental monitoring, food fermentation, industrial production, and clinical medicine. Optical oxygen sensors with high sensitivity, accuracy, stability, and anti-jamming capability for DO content detection have provoked scientists’ attention in recent years. In this work, we selected platinum octaethylporphine (PtOEP), low-density polyethylene (LDPE), and high-density polyethylene (HDPE) as the fluorescent indicator and matrix materials, respectively. Porous LDPE/PtOEP and HDPE/PtOEP oxygen-sensing films were constructed by incorporating PtOEP in PE via the phase-separation method. The optimum parameters were obtained as follows: the concentrations of LDPE and HDPE solutions were 0.010 mg/L, and PtOEP was 8 μg. Based on the above study, the effects of different kinds of PE on the performance of the oxygen-sensing film were studied in detail, finding that the LDPE/PtOEP oxygen-sensing film had better photostability and could measure the DO concentrations of several water samples accurately.
引用
收藏
页码:1439 / 1446
页数:7
相关论文
共 50 条
  • [41] Characterization of a fluorescent sol-gel encapsulated erythrosin B dissolved oxygen sensor
    Bailey, RT
    Cruickshank, FR
    Deans, G
    Gillanders, RN
    Tedford, MC
    ANALYTICA CHIMICA ACTA, 2003, 487 (01) : 101 - 108
  • [42] Design and research about the optical sensor of dissolved oxygen in water based on fluorescence quenching
    Li, Sun
    Wen-Yuan, Dai
    Jian, Bao
    Jin-zu, Wang
    3RD INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PARTS 1-3, 2007, 6723
  • [43] Study on Ratiometric Optical Fiber Dissolved Oxygen Sensor Based on Fluorescence Quenching Principle
    Qing-yang, Meng
    Zhang, Hong-xia
    Zhao, Yong-kun
    Jia, Da-gong
    Liu, Tie-gen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (09) : 2445 - 2449
  • [44] Prediction interval soft sensor for dissolved oxygen content estimation in an electric arc furnace
    Blazic, Aljaz
    Skrjanc, Igor
    Logar, Vito
    APPLIED SOFT COMPUTING, 2024, 167
  • [45] Electrochemical Dissolved Oxygen Sensor-Integrated Platform for Wireless In Situ Bioprocess Monitoring
    Stine, Justin M.
    Beardslee, Luke A.
    Sathyam, Rajendra M.
    Bentley, William E.
    Ghodssi, Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 320
  • [46] A Highly Miniaturized Dissolved Oxygen Sensor Using a Nanoporous Platinum Electrode Electroplated on Silicon
    Lee, Yi Jae
    Park, Jae Yeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (05) : 1505 - 1510
  • [47] Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber
    Wu, Lina
    Zhang, Xueji
    Ju, Huangxian
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (04) : 479 - 484
  • [48] Control of condensate dissolved oxygen in steam surface condenser. Reconstruction experience
    Vodeniktov, Artem
    Melnikova, Valeriia
    Minibaev, Azamat
    Lazarev, Nikita
    RESULTS IN ENGINEERING, 2022, 15
  • [49] Dissolved oxygen transfer along falling water jets with developing surface disturbance
    Lu, Jingying
    Li, Ran
    Wan, Hang
    Ma, Qian
    Li, Kefeng
    Zhu, David Z.
    Feng, Jingjie
    Yan, Zhongluan
    Sun, Gan
    Yu, Jiang
    Tang, Xiliang
    Xu, Huoqing
    Xue, Jingyang
    Li, Peng
    Feng, Jingjie (fengjingjie@scu.edu.cn), 1600, Elsevier B.V. (38): : 129 - 136
  • [50] EFFECTS OF DISSOLVED-OXYGEN IN HF SOLUTION ON SILICON SURFACE-MORPHOLOGY
    OGAWA, H
    ISHIKAWA, K
    SUZUKI, MT
    HAYAMI, Y
    FUJIMURA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (2B): : 732 - 736