The scalable XCAT voxelised phantom was used with the GATE Monte Carlo toolkit to investigate the effect of voxel size on dosimetry estimates of internally distributed radionuclide calculated using direct Monte Carlo simulation. A uniformly distributed Fluorine-18 source was simulated in the Kidneys of the XCAT phantom with the organ self dose (kidney ← kidney) and organ cross dose (liver ← kidney) being calculated for a number of organ and voxel sizes. Patient specific dose factors (DF) from a clinically acquired FDG PET/CT study have also been calculated for kidney self dose and liver ← kidney cross dose. Using the XCAT phantom it was found that significantly small voxel sizes are required to achieve accurate calculation of organ self dose. It has also been used to show that a voxel size of 2 mm or less is suitable for accurate calculations of organ cross dose. To compensate for insufficient voxel sampling a correction factor is proposed. This correction factor is applied to the patient specific dose factors calculated with the native voxel size of the PET/CT study.
引用
收藏
页码:495 / 503
页数:8
相关论文
共 50 条
  • [1] EFFECT OF VOXEL SIZE WHEN CALCULATING PATIENT SPECIFIC RADIONUCLIDE DOSIMETRY ESTIMATES USING DIRECT MONTE CARLO SIMULATION
    Hickson, K.
    O'Keefe, G.
    Scott, A. M.
    INTERNAL MEDICINE JOURNAL, 2012, 42 : 42 - 42
  • [2] Effect of voxel size when calculating patient specific radionuclide dosimetry estimates using direct Monte Carlo simulation
    Hickson, Kevin J.
    O'Keefe, Graeme J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 495 - 503
  • [3] Validation of a Patient-Specific Monte Carlo Targeted Radionuclide Therapy Dosimetry Platform
    Besemer, A.
    Bednarz, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 303 - 304
  • [4] PATIENT SPECIFIC DOSIMETRY OF EXTRAVASATION OF RADIOPHARMACEUTICALS USING MONTE CARLO
    Goodman, S.
    Smith, J.
    INTERNAL MEDICINE JOURNAL, 2015, 45 : 1 - 1
  • [5] A Voxel-Dose Algorithm of Heterogeneous Activity Distribution for Monte-Carlo Simulation of Radionuclide Therapy Dosimetry
    Lin, Hui
    Jing, Jia
    Cai, Jinfeng
    Xu, Liangfeng
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2012, 27 (06) : 344 - 352
  • [6] Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations
    Hadad, Kamal
    Saeedi-Moghadam, Mahdi
    Zeinali-Rafsanjani, Banafsheh
    TECHNOLOGY AND HEALTH CARE, 2017, 25 (01) : 29 - 35
  • [7] Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation
    Kinase, S
    Zankl, M
    Kuwabara, J
    Sato, K
    Noguchi, H
    Funabiki, J
    Saito, K
    RADIATION PROTECTION DOSIMETRY, 2003, 105 (1-4) : 557 - 563
  • [8] Optimizing the Combination of Targeted Radionuclide Therapy Agents Using a Multi-Scale Patient-Specific Monte Carlo Dosimetry Platform
    Besemer, A.
    Titz, B.
    Grudzinski, J.
    Weichert, J.
    Hall, L.
    Bednarz, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 282 - 282
  • [9] Influence of Phantom Voxel Size Setup On Monte Carlo Simulation in Gamma Knife Using EGSnrc
    Song, T.
    Chen, H.
    Zhou, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Monte-Carlo (MC) simulation and calculation of the specific absorbed fractions (SAFs) of radiation energy for internal dosimetry using a VOXEL phantom of a piglet
    Kranz, Mathias
    Sattler, Bernhard
    Desbree, Aurelie
    Rullmann, Michael
    Deuther-Conrad, Winnie
    Steinbach, Joerg
    Brust, Peter
    Sabri, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59