Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding

被引:0
作者
Nico Sollmann
Charlotte Rüther
Simon Schön
Claus Zimmer
Thomas Baum
Jan S. Kirschke
机构
[1] Technical University of Munich,Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar
[2] Technical University of Munich,TUM
[3] University Hospital Ulm,Neuroimaging Center, Klinikum rechts der Isar
来源
European Radiology Experimental | / 5卷
关键词
Clinical protocols; DIXON; Emergency service (hospital); Magnetic resonance imaging; Spine;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [32] Comparison of a deep learning-accelerated T2-weighted turbo spin echo sequence and its conventional counterpart for female pelvic MRI: reduced acquisition times and improved image quality
    Ren, Jing
    Li, Yuan
    Liu, Fei-Shi
    Liu, Chong
    Zhu, Jin-Xia
    Nickel, Marcel Dominik
    Wang, Xiao-Ye
    Liu, Xin-Yu
    Zhao, Jia
    He, Yong-Lan
    Jin, Zheng-Yu
    Xue, Hua-Dan
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [33] Comparison of a deep learning-accelerated T2-weighted turbo spin echo sequence and its conventional counterpart for female pelvic MRI: reduced acquisition times and improved image quality
    Jing Ren
    Yuan Li
    Fei-Shi Liu
    Chong Liu
    Jin-Xia Zhu
    Marcel Dominik Nickel
    Xiao-Ye Wang
    Xin-Yu Liu
    Jia Zhao
    Yong-Lan He
    Zheng-Yu Jin
    Hua-Dan Xue
    Insights into Imaging, 13
  • [34] Assessment of the distal anastomosis of coronary artery bypass grafts with a 2D T2-weighted turbo spin echo sequence and correlation to conventional coronary angiography
    Wittlinger, T
    Martinovic, I
    Moritz, A
    Kalden, P
    Kreitner, KF
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (02) : 219 - 225
  • [35] Assessment of coronary artery bypass graft patency with a 2D T2-weighted breath-hold Turbo-Spin-Echo sequence (HASTE)
    Kalden, P
    Kreitner, KF
    Wittlinger, T
    Voigtländer, T
    Krummenauer, F
    Schreiber, W
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 442 - 448
  • [36] Abdominal lymphoma staging:: Is MR imaging with T2-weighted turbo-spin-echo sequence a diagnostic alternative to contrast-enhanced spiral CT?
    Jung, G
    Heindel, W
    von Bergwelt-Baildon, M
    Bredenfeld, H
    Gossmann, A
    Zähringer, M
    Tesch, H
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (05) : 783 - 787
  • [37] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [38] High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    Schwenk, Arpad
    Alfieri, Alex
    Czell, David
    Wyss, Michael
    Wildi, Lukas
    Binkert, Christoph A.
    Sartoretti-Schefer, Sabine
    TOMOGRAPHY, 2022, 8 (01) : 257 - 266
  • [39] Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences
    Lee, Hoseok
    Ahn, Joong Mo
    Kang, Yusuhn
    Oh, Joo Han
    Lee, Eugene
    Lee, Joon Woo
    Kang, Heung Sik
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (02) : 320 - 327
  • [40] T2-weighted turbo spin-echo images, maximum-intensity projections, and three-dimensional volume-rendering for delineation of pathologies and anatomic details of the inner ear
    Krombach, GA
    Martiny, S
    Di Martino, E
    Westhofen, M
    Stanzel, S
    Haage, P
    Prescher, A
    Buecker, A
    Günther, RW
    INVESTIGATIVE RADIOLOGY, 2004, 39 (12) : 756 - 766