Enhanced 1D photonic crystal biosensor for blood components and blood infection detection

被引:2
|
作者
Nasr, Donia M. [1 ]
Mostafa, Samia I. [2 ]
El Naggar, Mona A. [2 ]
机构
[1] Akhbar Alyoum Acad, Elect & Commun Engn Dept, Giza, Egypt
[2] Cairo Univ, Fac Engn, Engn Phys & Math Dept, Cairo, Egypt
来源
EUROPEAN PHYSICAL JOURNAL D | 2024年 / 78卷 / 05期
关键词
CREATININE CONCENTRATION; BIOPHOTONIC SENSOR; DESIGN; PRESSURE; FILTER;
D O I
10.1140/epjd/s10053-024-00838-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The present work proposes a unidimensional asymmetric photonic crystal (1D PhC) sensor suitable for detecting blood components for both healthy and infected conditions. The proposed design is an enhanced efficient biosensor that distinguishes five blood components, namely; platelets, plasma, haemoglobin, RBCs and WBCs. The present work biosensor is designed as N binary nanostructured layers of SiO2 and PbS, with a defect layer, D, to form an asymmetric (P|Q)N/2D (P|Q)N/2 model. Infrared radiation is directed on the PhC in two cases: (i) normal incidence and (ii) oblique incidence with transverse electric mode (TEM) and transverse magnetic mode (TMM). The EMW propagation through the PhC layers is simulated using the well-established transfer matrix that is implemented using MATLAB software. The present work PhC design produces output transmission pulse peaks for all samples under investigation, both healthy and infected. The sensitivity, S, FoM, FWHM and Qf are calculated to assess the proposed biosensor performance. The presented biosensor exhibits better sensitivity (S), in the case of oblique incidence (TEM) than the normal incidence. Moreover, the performance of the proposed biosensor is validated by calculating another type of sensitivity (S ') for the five infected blood-component samples when related to their corresponding healthy ones. Furthermore, the variation of sensitivity with the angle of incidence is investigated showing a significant rise in the sensitivity with the increase in the incident angle. The proposed biosensor exhibits maximum sensitivity; Smax = 625.0 nm/RIU for infected plasma in the case of normal incidence, while Smax = 1025.4 nm/RIU for infected Hb (TEM) and Smax = 675.0 nm/RIU for infected WBCs (TMM). The proposed PhC biosensor is capable of early detection of some diseases such as leukaemia, dengue virus and malaria. The proposed biosensor performance is compared to recent literature exhibiting higher sensitivity, thus presenting an accurate method of further blood disease detection.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Modeling the Photonic Crystal Fiber based Surface Plazmon Resonance Biosensor to Detect Blood Components
    Yasli, Ahmet
    Ademgil, Huseyin
    29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [32] Designing a Multichannel Nanocavity Coupled Photonic Crystal Biosensor for Detection of Glucose Concentration in Blood
    Ameta, Shivani
    Sharma, Arvind
    Inaniya, Pawan Kumar
    2017 8TH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION AND NETWORKING TECHNOLOGIES (ICCCNT), 2017,
  • [33] Nanocavity-Coupled Waveguide Photonic Crystal Biosensor for Detection of Hemoglobin Concentration in Blood
    Ameta, Shivani
    Sharma, Arvind
    Inaniya, Pawan Kumar
    OPTICAL AND WIRELESS TECHNOLOGIES, OWT 2017, 2018, 472 : 247 - 253
  • [34] Graphene-based 1D defective photonic crystal biosensor for real-time detection of cancer cells
    Abinash Panda
    Puspa Devi Pukhrambam
    Feng Wu
    Walid Belhadj
    The European Physical Journal Plus, 136
  • [35] Graphene-based 1D defective photonic crystal biosensor for real-time detection of cancer cells
    Panda, Abinash
    Pukhrambam, Puspa Devi
    Wu, Feng
    Belhadj, Walid
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (08):
  • [36] Vitiligo detection capabilities of 1D photonic crystal biosensing design
    Alshomrany, Ali S.
    Aly, Arafa H.
    Mohamed, B. A.
    Alamri, S.
    Mohamed, D.
    Awasthi, S. K.
    Matar, Zinab. S.
    Amin, A. F.
    Hanafy, H.
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [37] 1D topological photonic crystal based nanosensor for tuberculosis detection
    Thara, R. Lakshmi
    Priya, P. Aruna
    NANOTECHNOLOGY, 2024, 35 (41)
  • [38] Design of a 2D photonic crystal biosensor using X-shape ring resonator based on Graphene Oxide (GO) for detection of blood components
    Baraty, Fatemeh
    Hamedi, Samaneh
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2022, 36 (17) : 2401 - 2418
  • [39] Performance analysis of photonic crystal based biosensor for the detection of bio-molecules in urine and blood
    Yashaswini P.R.
    Gayathri H.N.
    Srikanth P.C.
    Materials Today: Proceedings, 2023, 80 : 2247 - 2254
  • [40] Plasmonic Biosensor With Gold and Titanium Dioxide Immobilized on Photonic Crystal Fiber for Blood Composition Detection
    Chaudhary, Vijay Shanker
    Kumar, Dharmendra
    Mishra, Gyan Prakash
    Sharma, Sneha
    Kumar, Santosh
    IEEE SENSORS JOURNAL, 2022, 22 (09) : 8474 - 8481