Long-term (≥2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results

被引:0
作者
Tae-Hoon Kim
Jung-Sun Kim
Byoung-Keuk Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
机构
[1] Yonsei University College of Medicine,Division of Cardiology, Severance Cardiovascular Center
[2] Yonsei University College of Medicine,Severance Biomedical Science Institute
来源
The International Journal of Cardiovascular Imaging | 2011年 / 27卷
关键词
Stent; Optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Many studies have demonstrated that late or very late thrombosis after drug-eluting stent (DES) implantation may be related with incomplete neointimal coverage. We investigated long-term (≥2 years) results of neointimal coverage following sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) implantation using optical coherence tomography (OCT). A follow-up angiography with OCT examination was performed in 29 patients with 32 lesions for more than 2 years (group 1; 1,066 ± 381 days) and 101 patients with 104 lesions at 9 months (group 2; 273 ± 33 days) after the index procedure. The status of neointimal coverage and stent apposition was evaluated. The number of stents with completely covered struts was higher (25.0% in group 1 vs. 13.5% in group 2, P = 0.12). The percentage of uncovered struts (5.4 ± 7.5% in group 1 vs. 8.5 ± 11.6% in group 2, P = 0.19) and that of malapposed strut (0.5 ± 1.4% vs. 1.5 ± 4.2%, respectively, P = 0.19) were lower in group 1. While the percentage of uncovered and malapposed struts were quite similar in the PES groups between the two groups (P = 0.54 and 0.65, respectively), there were lower trends in the percentage of uncovered and malapposed struts in the SES group (P = 0.09 and 0.09, respectively). In conclusion, incomplete neointimal coverage was still observed in a majority of DESs and considerable struts were not covered with neointima even at more than 2 years after DES implantation. The pattern of neointimal coverage between 9-month and 2-year appeared to be somewhat different between PES and SES.
引用
收藏
页码:875 / 881
页数:6
相关论文
共 50 条
  • [1] Long-term (≥2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results
    Kim, Tae-Hoon
    Kim, Jung-Sun
    Kim, Byoung-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (06) : 875 - 881
  • [2] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775
  • [3] Long-term follow-up after drug eluting stent implantation in left main trifurcations
    Tamburino, Corrado
    Tomasello, Salvatore Davide
    Capodanno, Davide
    Di Salvo, Maria Elena
    Marza, Francesco
    Galassi, Alfredo Ruggero
    EUROINTERVENTION, 2009, 5 (04) : 432 - 437
  • [4] Six-month follow-up evaluation for everolimus-eluting stents by intracoronary optical coherence tomography: Comparison with paclitaxel-eluting stents
    Takano, Masamichi
    Murakami, Daisuke
    Yamamoto, Masanori
    Kurihara, Osamu
    Murai, Koji
    Inami, Toru
    Kimata, Nakahisa
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 181 - 186
  • [5] Long-Term Follow-up of Neointimal Coverage of Sirolimus-Eluting Stents - Evaluation With Optical Coherence Tomography -
    Ishigami, Ken-ichi
    Uemura, Shiro
    Morikawa, Yoshinobu
    Soeda, Tsunenari
    Okayama, Satoshi
    Nishida, Taku
    Takemoto, Yasuhiro
    Onoue, Kenji
    Somekawa, Satoshi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Saito, Yoshihiko
    CIRCULATION JOURNAL, 2009, 73 (12) : 2300 - 2307
  • [6] Comparison by Optical Coherence Tomography of Paclitaxel-Eluting Stents With Sirolimus-Eluting Stents Implanted in One Coronary Artery in One Procedure - 6-Month Follow-up
    Miyoshi, Naoki
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Kawamori, Hiroyuki
    Kato, Hiroki
    Yoshino, Naoki
    Kozuki, Amane
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2010, 74 (05) : 903 - 908
  • [7] Treatment of in-stent restenosis using a paclitaxel-eluting stent:: acute results and long-term follow-up of a matched-pair comparison with intracoronary β-radiation therapy
    Radke, PW
    Kobella, S
    Kaiser, A
    Franke, A
    Schubert, D
    Grube, E
    Hanrath, P
    Hoffman, R
    EUROPEAN HEART JOURNAL, 2004, 25 (11) : 920 - 925
  • [8] Ten-Year Clinical Follow-up After Sirolimus-Eluting Stent Implantation
    Nuno, Palhais
    Arroyo, Diego
    Lehmann, Sonja
    Togni, Mario
    Aufmann, Urs
    Stauffer, Jean-Christophe
    Goy, Jean-Jacques
    Cook, Stephane
    CIRCULATION, 2013, 128 (22)
  • [9] Long-Term Vascular Healing in Response to Sirolimus- and Paclitaxel-Eluting Stents An Optical Coherence Tomography Study
    Raber, Lorenz
    Baumgartner, Sandro
    Garcia, Hector M. Garcia
    Kalesan, Bindu
    Justiz, Joern
    Pilgrim, Thomas
    Moschovitis, Aris
    Khattab, Ahmed A.
    Buellesfeld, Lutz
    Wenaweser, Peter
    Meier, Bernhard
    Serruys, Patrick W.
    Jueni, Peter
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (09) : 946 - 957
  • [10] Serial optical coherence tomography assessments at 2- and 4-month follow-up after paclitaxel-eluting stenting of the superficial femoral artery
    Aihara H.
    Soga Y.
    Kuramitsu S.
    Cardiovascular Intervention and Therapeutics, 2015, 30 (2) : 138 - 141