Disulfide-modified antigen for detection of celiac disease-associated anti-tissue transglutaminase autoantibodies

被引:0
作者
Luis Carlos Rosales-Rivera
Samuel Dulay
Pablo Lozano-Sánchez
Ioanis Katakis
Josep Lluís Acero-Sánchez
Ciara K. O’Sullivan
机构
[1] Universitat Rovira i Virgili,Departamento de Ingeniería Química
[2] Universidad de Guadalajara,undefined
[3] Integrated Microsystems for Quality of Life,undefined
[4] Institució Catalana de Recerca i Estudis Avançats,undefined
来源
Analytical and Bioanalytical Chemistry | 2017年 / 409卷
关键词
Electrochemical immunosensor; Modified proteins; Anti-tissue transglutaminase antibodies; Celiac disease;
D O I
暂无
中图分类号
学科分类号
摘要
A simple and rapid immunosensor for the determination of the celiac disease-related antibody, anti-tissue transglutaminase, was investigated. The antigenic protein tissue transglutaminase was chemically modified, introducing disulfide groups through different moieties of the molecule (amine, carboxylic, and hydroxyl groups), self-assembled on gold surfaces, and used for the detection of IgA and IgG autoantibodies. The modified proteins were evaluated using enzyme-linked immunosorbent assay and surface plasmon resonance, which showed that only introduction of the disulfide groups through amine moieties in the tissue transglutaminase preserved its antigenic properties. The disulfide-modified antigen was co-immobilized via chemisorption with a poly(ethylene glycol) alkanethiol on gold electrodes. The modified electrodes were then exposed to IgA anti-tissue transglutaminase antibodies and subsequently to horseradish peroxidase-labeled anti-idiotypic antibodies, achieving a detection limit of 260 ng ml−1. Immunosensor performance in the presence of complex matrixes, including clinically relevant serum reference solutions and real patient samples, was evaluated. The introduction of disulfides in the antigenic protein enabled a simple and convenient one-step surface immobilization procedure involving only spontaneous gold-thiol covalent binding. Complete amperometric assay time was 30 min.
引用
收藏
页码:3799 / 3806
页数:7
相关论文
共 252 条
[1]  
Willmott C(2010)Point-of-care testing Surgery 28 159-160
[2]  
Arrowsmith JE(2016)Electrochemical biosensors for fast detection of food contaminants—trends and perspective TrAC Trends Anal Chem 79 80-87
[3]  
Gregory K(2012)Electrochemical immunosensors for detection of cancer protein biomarkers ACS Nano 6 6546-6561
[4]  
Lewandrowski K(2014)A label-free immunosensor based on graphene nanocomposites for simultaneous multiplexed electrochemical determination of tumor markers Biosens Bioelectron 53 160-166
[5]  
Lee-Lewandrowski E(2013)An electrochemical immunosensor for sensitive detection of Biosens Bioelectron 49 485-491
[6]  
Lewandrowski K(2016) O157:H7 using C60 based biocompatible platform and enzyme functionalized Pt nanochains tracing tag Anal Chim Acta 908 8-21
[7]  
Lewandrowski K(2008)New advances in electrochemical biosensors for the detection of toxins: nanomaterials, magnetic beads and microfluidics systems. A review TrAC Trends Anal Chem 27 771-784
[8]  
van Cott EM(2014)Capillary-based immunoassays, immunosensors and DNA sensors – steps towards integration and multi-analysis Carbon N Y 79 654-663
[9]  
Rotariu L(2012)Spongy graphene electrode in electrochemical detection of leukemia at single-cell levels Biosens Bioelectron 33 134-138
[10]  
Lagarde F(2011)Amperometric immunosensor for the determination of IgA deficiency in human serum samples Biosens Bioelectron 26 3852-3856