Evaluation of modified Hilhorst models for pore electrical conductivity estimation using a low-cost dielectric sensor

被引:0
作者
Nessrine Zemni
Fethi Bouksila
Fairouz Slama
Magnus Persson
Ronny Berndtsson
Rachida Bouhlila
机构
[1] University of Carthage,National Institute for Research in Rural Engineering, Water, and Forestry (INRGREF), LR20INRGREF04 Rural Engineering
[2] University of Tunis El Manar,National Engineering School of Tunis (ENIT), 2LR99ES19 Laboratory of Modelling in Hydraulics and Environment (LMHE)
[3] Lund University,Division of Water Resources Engineering
[4] Lund University,Centre for Advanced Middle Eastern Studies
关键词
Soil salinity; Soil water content; FDR; TDR; WET sensor;
D O I
10.1007/s12517-022-10354-5
中图分类号
学科分类号
摘要
Real-time measurement of soil water content (θ) and pore electrical conductivity (ECp) is essential to improve water irrigation efficiency and agricultural productivity. Low-cost frequency domain reflectometry (FDR) sensors are now representing a powerful tool for irrigation management purposes. However, compared to the time domain reflectometry (TDR), FDR sensors’ accuracy to predict θ and ECp is negatively affected by saline conditions. Thus, it is necessary to determine the soil salinity range where FDR probes are not recommended in precise irrigated agriculture and to select the appropriate models for ECp estimation especially under saline conditions. Low-cost sensors, however, often use the default Hilhorst model for ECp determination, and in salty soils, this use is not correct. Thus, we present a new and improved Hilhorst model of ECp estimation. We also assess the performance of the low-cost Water, Electrical conductivity, and Temperature (WET) sensor and to test the new ECp model under saline conditions. Consequently, the ECp was predicted using, first, a polynomial model in which ECa effect on the soil parameter K0 is considered and second, a linear model in which the ECa effect on soil apparent dielectric permittivity Ka is considered. The performance of the proposed models is evaluated by measurements of the WET sensor in sandy porous media collected in the Tunisian Jemna oasis using seven different levels of NaCl solutions (0.02 to 8.2 dSm−1) and compared to TDR measurements. Results show that using the default Hilhorst model, the root mean square error (RMSE) of ECp predictions was higher than 0.5 dSm−1 using WET sensor. However, if considering the bulk electrical conductivity (ECa) effect on the soil parameter K0 instead of using the standard values in the Hilhorst model, the performance of the WET sensor to predict ECp increased with a mean RMSE equal to 0.1 dSm−1.
引用
收藏
相关论文
共 63 条
[1]  
Bouksila F(2013)Assessment of soil salinization risks under irrigation with brackish water in semiarid Tunisia Environ Exp Bot 92 176-185
[2]  
Bahri A(2008)Soil water content and salinity determination using different dielectric methods in saline gypsiferous soil Hydrol Sci J 53 253-265
[3]  
Berndtsson R(2020)Performance of soil moisture sensors in Florida sandy soils Water 12 358-1078
[4]  
Persson M(2003)Soil solution electrical conductivity measurements using different dielectric techniques Soil Sci Soc Am J 67 1071-1925
[5]  
Rozema J(2000)A pore water conductivity sensor Soil Sci Soc Am J 64 1922-558
[6]  
Van der Zee SEATM(2010)Evaluation of a dielectric sensor for measurement of soil-water electrical conductivity J Irrig Drain Eng 136 553-328
[7]  
Bouksila F(2017)Prediction of soil solution electrical conductivity by the permittivity corrected linear model using a dielectric sensor J Irrig Drain Eng 143 04017030-514
[8]  
Persson M(1986)A method of measuring soil moisture by time-domain reflectometry J Hydrol 88 319-1076
[9]  
Berndtsson R(1999)Evaluating soil salinity status from bulk electrical conductivity and permittivity Eur J Soil Sci 50 505-80
[10]  
BahriI A(1999)Practical aspects of salinity effect on TDR-measured water content: a field study Soil Sci Soc Am J 63 1070-277