Non-enzymatic analysis of glucose on printed films based on multi-walled carbon nanotubes

被引:0
作者
Nikos G. Tsierkezos
Uwe Ritter
Nora Wetzold
Arved Carl Hübler
机构
[1] Technische Universität Ilmenau,Institut für Chemie und Biotechnik
[2] Technische Universität Chemnitz,Institut für Print
来源
Microchimica Acta | 2012年 / 179卷
关键词
Enzyme-free sensor; Glucose; Multi-walled carbon nanotubes; Flexographic printing process; Polycarbonate substrate;
D O I
暂无
中图分类号
学科分类号
摘要
We report on the fabrication of an enzyme–free electrochemical sensor for glucose based on a printed film consisting of multi–walled carbon nanotubes (MWCNTs). The MWCNT–based film can be produced by means of a flexographic printing process on a polycarbonate (PC) substrate. The electrochemical response of the MWCNT–based film (referred to as MWCNT–PC) towards the oxidation of glucose at pH 7 was studied by means of cyclic voltammetry and electrochemical impedance spectroscopy. The MWCNT–PC film exhibits substantial electrocatalytic activity towards the oxidation of glucose at an anodic potential of 0.30 V (vs. Ag/AgCl). The findings reveal that the MWCNT–PC film enables non–enzymatic sensing of glucose with a detection limit as low as 2.16 μM and a sensitivity of 1045 μA∙mM−1∙cm−2.
引用
收藏
页码:157 / 161
页数:4
相关论文
共 105 条
[1]  
Shaw JE(2010)Global estimates of the prevalence of diabetes for 2010 and 2030 Diabetes Res Clin Pract 87 4-14
[2]  
Sicree RA(1992)Can continuous glucose monitoring be used for the treatment of diabetes Anal Chem 64 381-386
[3]  
Zimmet PZ(1998)Biosensors: blockbuster or bomb? Electrochemical biosensors for diabetes monitoring Electrochem Soc Interface 7 26-33
[4]  
Reach G(2001)Capacitive detection of glucose using molecularly imprinted Polymers Biosens Bioelectron 16 179-185
[5]  
Wilson GS(2009)Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection Sens Actuators B 142 216-223
[6]  
Kuhn LS(2010)Pulse-voltammetric glucose detection at gold junction electrodes Anal Chem 82 7063-7067
[7]  
Cheng Z(1993)Chronoamperometric detection of glucose by a third generation biosensor constructed from conducting microtubules of polypyrrole Synth Met 57 3689-3695
[8]  
Wang E(2011)Nonenzymatic amperometric glucose sensor based on nanoporous gold/ruthenium electrode Electroanalysis 23 2057-2062
[9]  
Yang X(1993)Developing glucose sensors for in vivo use Trends Biotechnol 11 285-291
[10]  