Principal component analysis to assess the efficiency and mechanism for enhanced coagulation of natural algae-laden water using a novel dual coagulant system

被引:0
作者
Hua-Se Ou
Chao-Hai Wei
Yang Deng
Nai-Yun Gao
Yuan Ren
Yun Hu
机构
[1] South China University of Technology,The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, College of Environment and Energy
[2] Higher Education Mega Center,Department of Earth and Environmental Studies
[3] Montclair State University,State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering
[4] Tongji University,undefined
[5] Guangzhou Higher Education Mega Center,undefined
来源
Environmental Science and Pollution Research | 2014年 / 21卷
关键词
Coagulation; Algae-laden water; Polyaluminum chloride sulfate; Polydiallyldimethylammonium chloride; CDOM; PCA;
D O I
暂无
中图分类号
学科分类号
摘要
A novel dual coagulant system of polyaluminum chloride sulfate (PACS) and polydiallyldimethylammonium chloride (PDADMAC) was used to treat natural algae-laden water from Meiliang Gulf, Lake Taihu. PACS (Aln(OH)mCl3n-m-2k(SO4)k) has a mass ratio of 10 %, a SO42−/Al3+ mole ratio of 0.0664, and an OH/Al mole ratio of 2. The PDADMAC ([C8H16NCl]m) has a MW which ranges from 5 × 105 to 20 × 105 Da. The variations of contaminants in water samples during treatments were estimated in the form of principal component analysis (PCA) factor scores and conventional variables (turbidity, DOC, etc.). Parallel factor analysis determined four chromophoric dissolved organic matters (CDOM) components, and PCA identified four integrated principle factors. PCA factor 1 had significant correlations with chlorophyll-a (r = 0.718), protein-like CDOM C1 (0.689), and C2 (0.756). Factor 2 correlated with UV254 (0.672), humic-like CDOM component C3 (0.716), and C4 (0.758). Factors 3 and 4 had correlations with NH3-N (0.748) and T-P (0.769), respectively. The variations of PCA factors scores revealed that PACS contributed less aluminum dissolution than PAC to obtain equivalent removal efficiency of contaminants. This might be due to the high cationic charge and pre-hydrolyzation of PACS. Compared with PACS coagulation (20 mg L−1), the removal of PCA factors 1, 2, and 4 increased 45, 33, and 12 %, respectively, in combined PACS–PDADMAC treatment (0.8 mg L−1 + 20 mg L−1). Since PAC contained more Al (0.053 g/1 g) than PACS (0.028 g/1 g), the results indicated that PACS contributed less Al dissolution into the water to obtain equivalent removal efficiency.
引用
收藏
页码:2122 / 2131
页数:9
相关论文
共 103 条
[1]  
Boehme J(2004)Examining CDOM fluorescence variability using principal component analysis: seasonal and regional modeling of three-dimensional fluorescence in the Gulf of Mexico Mar Chem 89 3-14
[2]  
Coble P(2007)Organic polyelectrolytes in water treatment Water Res 41 2301-2324
[3]  
Conmy R(1997)PARAFAC. Tutorial and applications Chemometr Intell Lab 38 149-171
[4]  
Stovall-Leonard A(1999)Effects of polydiallyldimethyl ammonium chloride coagulant on formation of chlorinated by-products in drinking water Chemosphere 39 1333-1346
[5]  
Bolto B(2003)Fluorescence excitation—emission matrix regional integration to quantify spectra for dissolved organic matter Environ Sci Technol 37 5701-5710
[6]  
Gregory J(1996)Characterization of marine and terrestrial DOM in seawater using excitation—emission matrix spectroscopy Mar Chem 51 325-346
[7]  
Bro R(2012)The dynamics of toxic Microcystis strains and microcystin production in two hypertrofic South African reservoirs Harmful Algae 20 1-10
[8]  
Chang EE(2009)The effects of temperature and nutrients on the growth and dynamics of toxic and nontoxic strains of Microcystis during cyanobacteria blooms Harmful Algae 8 715-725
[9]  
Chiang PC(2005)Natural organic matter(NOM) removal from surface water by coagulation J Environ Sci-China 17 119-122
[10]  
Chao SH(2001)Distribution of aluminum species and the characteristics of structure of poly-aluminum-chloride-sulfate (PACS) J Environ Sci-China 13 108-114