Prediction of postoperative motor deficits using intraoperative motor-evoked potentials in middle cerebral artery aneurysm

被引:0
作者
Dongze Guo
Xing Fan
Hao You
Xiaorong Tao
Lei Qi
Miao Ling
Zhibao Li
Jiajia Liu
Hui Qiao
机构
[1] Beijing Neurosurgical Institute,Department of Neurophysiology
[2] Capital Medical University,undefined
来源
Neurosurgical Review | 2021年 / 44卷
关键词
Intraoperative neurophysiological monitoring; Middle cerebral artery aneurysm; Motor-evoked potentials; Postoperative motor deficits;
D O I
暂无
中图分类号
学科分类号
摘要
To explore the relationship between postoperative motor deficits and the duration of reduced motor-evoked potentials (MEPs) in patients with middle cerebral artery (MCA) aneurysm. This study included 285 cases of MCA aneurysm treated with clipping surgery with MEP monitoring. The effects of MEP changes on postoperative motor function were assessed, and the key time point for minimizing the incidence of postoperative motor dysfunction was found through receiver operating characteristic (ROC) curve analysis. Motor dysfunction was significantly associated with the occurrence of MEP changes, and patients with irreversible changes were more likely to suffer motor dysfunction than were those with reversible changes. The critical duration of MEP changes that minimized the risk of postoperative motor dysfunction was 8.5 min. This study revealed that MEP monitoring is an effective method for preventing ischemic brain injury during surgical treatment of MCA aneurysm and proposes a critical cutoff for the duration of MEP deterioration of 8.5 min for predicting postoperative motor dysfunction.
引用
收藏
页码:495 / 501
页数:6
相关论文
共 83 条
[11]  
Kim JE(2003)Intraoperative monitoring of blood flow insufficiency in the anterior choroidal artery during aneurysm surgery J Neurosurg 98 507-383
[12]  
Guo L(2006)Monitoring of muscle motor evoked potentials during cerebral aneurysm surgery: intraoperative changes and postoperative outcome J Neurosurg 105 675-undefined
[13]  
Gelb AW(2017)Diagnostic accuracy of motor evoked potentials to detect neurological deficit during idiopathic scoliosis correction: a systematic review J Neurosurg Spine 26 374-undefined
[14]  
Horiuchi K(2017)The diagnostic accuracy of evoked potential monitoring techniques during intracranial aneurysm surgery for predicting postoperative ischemic damage: a systematic review and meta-analysis World Neurosurg 103 e823-undefined
[15]  
Suzuki K(undefined)undefined undefined undefined undefined-undefined
[16]  
Sasaki T(undefined)undefined undefined undefined undefined-undefined
[17]  
Matsumoto M(undefined)undefined undefined undefined undefined-undefined
[18]  
Sakuma J(undefined)undefined undefined undefined undefined-undefined
[19]  
Konno Y(undefined)undefined undefined undefined undefined-undefined
[20]  
Oinuma M(undefined)undefined undefined undefined undefined-undefined