Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT

被引:0
|
作者
Tiziano Schepis
Oliver Gaemperli
Pascal Koepfli
Christine Rüegg
Cyrill Burger
Sebastian Leschka
Lotus Desbiolles
Lars Husmann
Hatem Alkadhi
Philipp A. Kaufmann
机构
[1] University Hospital Zurich,Clinic of Nuclear Medicine, Nuclear Cardiology
[2] University Hospital Zurich,Institute of Diagnostic Radiology
[3] University of Zurich,Centre for Integrative Human Physiology
[4] University Hospital Zurich,Cardiovascular Center
来源
European Journal of Nuclear Medicine and Molecular Imaging | 2007年 / 34卷
关键词
SPECT-CT; Attenuation correction; Multislice computed tomography; Coronary calcium score;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:11 / 19
页数:8
相关论文
共 43 条
  • [21] Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?
    Christian Wenning
    Kambiz Rahbar
    Alexis Vrachimis
    Otmar Schober
    Michael Schäfers
    Lars Stegger
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 1069 - 1076
  • [22] Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?
    Wenning, Christian
    Rahbar, Kambiz
    Vrachimis, Alexis
    Schober, Otmar
    Schaefers, Michael
    Stegger, Lars
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (07) : 1069 - 1076
  • [23] Clinical evaluation of the computed tomography attenuation correction map for myocardial perfusion imaging: the potential for incidental pathology detection
    Tootell, Andrew
    Vinjamuri, Sobhan
    Elias, Mark
    Hogg, Peter
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1122 - 1126
  • [24] Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography
    Caobelli, Federico
    Akin, Muharrem
    Thackeray, James T.
    Brunkhorst, Thomas
    Widder, Julian
    Berding, Georg
    Burchert, Ina
    Bauersachs, Johann
    Bengel, Frank M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) : 1036 - 1043
  • [25] Association of neutrophil/lymphocyte ratio with obstructive coronary artery disease and coronary artery calcium score detected by multislice computed tomography in type 2 diabetes mellitus patients
    Aygun, Fatih
    Efe, Duran
    PATIENT PREFERENCE AND ADHERENCE, 2015, 9 : 1023 - 1031
  • [26] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Marvin Grossmann
    Andreas A. Giannopoulos
    Fabiola A. Bechtiger
    Michael Messerli
    Moritz Schwyzer
    Dominik C. Benz
    Ken Kudura
    Catherine Gebhard
    Christoph Gräni
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    Journal of Nuclear Cardiology, 2020, 27 : 228 - 237
  • [27] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Grossmann, Marvin
    Giannopoulos, Andreas A.
    Bechtiger, Fabiola A.
    Messerli, Michael
    Schwyzer, Moritz
    Benz, Dominik C.
    Kudura, Ken
    Gebhard, Catherine
    Graeni, Christoph
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (01) : 228 - 237
  • [28] Diagnostic performance of cardiac fusion images from myocardial perfusion imaging and multislice computed tomography coronary angiography for assessment of hemodynamically significant coronary artery lesions: an observational study
    Kadokami, Toshiaki
    Ando, Shin-ichi
    Momii, Hidetoshi
    Yoshida, Masayoshi
    Narita, Sumito
    Fukunaga, Tomohisa
    Nishi, Jun-ichiro
    Tamura, Akira
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (01) : 60 - 68
  • [29] Role of Attenuation Correction to Discriminate Defects Caused by Left Bundle Branch Block Versus Coronary Stenosis in Single Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Hoefflinghaus, Tobias
    Husmann, Lars
    Valenta, Ines
    Moonen, Clemens
    Gaemperli, Oliver
    Schepis, Tiziano
    Namdar, Mehdi
    Koepfli, Pascal
    Siegrist, Patrick T.
    Kaufmann, Philipp A.
    CLINICAL NUCLEAR MEDICINE, 2008, 33 (11) : 748 - 751
  • [30] Incremental Predictive Value of Coronary Calcium Score in Risk Stratification of Coronary Revascularization in Patients With Normal or Mild Ischemia Using Nuclear Myocardial Perfusion Single Photon Emission Computed Tomography
    Suzuki, Yasuyuki
    Matsumoto, Naoya
    Nagumo, Sakura
    Matsuo, Rei
    Kuronuma, Keiichiro
    Ashida, Tadashi
    Tani, Shigemasa
    Yoda, Shunichi
    Amano, Yasuo
    Okumura, Yasuo
    CIRCULATION JOURNAL, 2021, 85 (06) : 877 - 882