Echocardiographic Evaluation of Prosthetic Heart Valves

被引:0
作者
Haïfa Mahjoub
Philippe Pibarot
Jean-Gaston Dumesnil
机构
[1] Laval University,Institut Universitaire de Cardiologie et de Pneumologie de Québec / Québec Heart and Lung Institute, Department of Medicine
来源
Current Cardiology Reports | 2015年 / 17卷
关键词
Prosthetic heart valves; Transcatheter heart valves; Doppler echocardiography; Stenosis; Regurgitation;
D O I
暂无
中图分类号
学科分类号
摘要
The specific flow pattern and imaging features of prosthetic heart valves poses major challenges for the Doppler echocardiographic assessment of prosthetic valve structure and function. A comprehensive approach that integrates several semi-quantitative and quantitative parameters obtained from multiple views is key to appropriately detect and quantitate prosthetic valve dysfunction and complications. In patients with prosthetic valves, and particularly in those with mitral prostheses, transesophageal echocardiography is often required to confirm and/or complement information obtained by transthoracic echocardiography. Three-dimensional echocardiography may provide incremental information for the identification of the underlying etiology of prosthetic valve stenosis or regurgitation. Transcatheter aortic valve implantation has rapidly expanded in the past 10 years and paravalvular regurgitation is frequent following this procedure. Given that paravalvular regurgitant jets are often multiple, irregular, and eccentric, the grading of this type of regurgitation is particularly challenging and requires an integrative multiwindow, multiplane, multiparametric approach.
引用
收藏
相关论文
共 78 条
[1]  
Yacoub MH(2005)Will heart valve tissue engineering change the world? Nat Clin Pract Cardiovasc Med 2 60-1
[2]  
Takkenberg JJ(2013)Transcatheter aortic valve implantation (TAVI): valve design and evolution Int J Cardiol 168 1822-31
[3]  
Fanning JP(2000)Transesophageal echocardiographic (TEE) evaluation of prosthetic valves Cardiol Clin 18 751-71
[4]  
Platts DG(2013)Now you see it, now you don’t: 3D echocardiographic evaluation of a prosthetic aortic valve J Cardiothorac Vasc Anesth 27 1060-3
[5]  
Walters DL(2013)Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy J Am Coll Cardiol Img 6 196-205
[6]  
Fraser JF(2009)Prosthetic heart valves: selection of the optimal prosthesis and long-term management Circulation 119 1034-48
[7]  
Bach DS(2007)Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival Circulation 115 2856-64
[8]  
Gerstein NS(2011)EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease Eur Heart J 32 2189-214
[9]  
Copeland SG(2013)Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestimation by Doppler J Am Soc Echocardiogr 26 791-800
[10]  
Kratzert WB(2012)Doppler echocardiographic evaluation of prosthetic valve function Heart 98 69-78