A methodological framework to relate the earthquake-induced frequency reduction to structural damage in masonry buildings

被引:0
作者
Daniele Sivori
Serena Cattari
Marco Lepidi
机构
[1] University of Genoa,Department of Civil, Chemical and Environmental Engineering (DICCA)
来源
Bulletin of Earthquake Engineering | 2022年 / 20卷
关键词
Structural monitoring; Seismic damage; Masonry buildings; Equivalent frame; Nonlinear dynamic analyses; Experimental modal analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The diffusion of seismic structural health monitoring systems, evaluating the dynamic response of engineering structures to earthquakes, is growing significantly among strategic buildings. The increasing availability of valuable vibration data is being backed by continuously evolving techniques for analysing and assessing structural health and damage. Within this framework, the paper proposes a novel model-driven vibration-based methodology to support the assessment of the damage level in masonry buildings hit by earthquakes. The leading idea is to exploit, in the pre-event phase, synthetic equivalent-frame modelling and nonlinear dynamic analyses to systematically relate the gradual reduction of natural frequencies to increasing levels of structural damage. The resulting behavioural chart (seismic chart) of the building, constructed by employing computational tools and robustly defined on a statistical base, may provide the theoretical expectation to ascertain a certain level of seismic damage, based on the decrease in vibration frequency experimentally identified in the post-event phase. The methodology is firstly formalized, integrating common identification techniques with a novel damage grade estimation procedure, and finally exemplified for a monitored strategic masonry building damaged by the 2016–2017 Central Italy earthquake sequence. The outcomes of this application confirm the operational validity of the methodology, which can be intended as effective support for the decision-making process regarding structural usability and safety in the post-earthquake scenario.
引用
收藏
页码:4603 / 4638
页数:35
相关论文
共 329 条
  • [1] Acunzo G(2022)Application of genetic algorithms for a new approach for seismic building monitoring: integrated measurement systems with physical and virtual sensors Bull Earthq Eng 37 14-23
  • [2] Fiorini N(2003)The modal assurance criterion-twenty years of use and abuse Sound Vib 247 113218-1764
  • [3] Spina D(2021)Seismic fragility assessment of existing masonry buildings in aggregate Eng Struct 49 1758-1198
  • [4] Dolce M(2020)Influence of seismic strain rates on the co-and post-seismic response of civil engineering buildings Earthq Eng Struct Dyn 2 e12228-1981
  • [5] Allemang RJ(2020)Structural health building response induced by earthquakes: material softening and recovery Eng Rep 108 1185-1289
  • [6] Angiolilli M(2018)Nonlinear elasticity observed in buildings during a long sequence of earthquakes Bul Seismol Soc Am 18 1966-542
  • [7] Lagomarsino S(2019)Recovery of the resonance frequency of buildings following strong seismic deformation as a proxy for structural health Struct Health Monit 132 106093-622
  • [8] Cattari S(2020)R2R-EU: software for fragility fitting and evaluation of estimation uncertainty in seismic risk analysis Soil Dyn Earthq Eng 124 1281-248
  • [9] Degli Abbati S(1998)Three proposals for characterizing MDOF nonlinear seismic response J Struct Eng 11 521-95
  • [10] Astorga A(2013)Review of strength models for masonry spandrels Bull Earthq Eng 16 607-1211