Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit

被引:0
作者
Nicolas Langwieser
Luisa Prechtl
Agnes S. Meidert
Alexander Hapfelmeier
Christian Bradaric
Tareq Ibrahim
Karl-Ludwig Laugwitz
Roland M. Schmid
Julia Y. Wagner
Bernd Saugel
机构
[1] I. Medizinische Klinik und Poliklinik,
[2] Klinikum rechts der Isar der Technischen Universität München,undefined
[3] II. Medizinische Klinik und Poliklinik,undefined
[4] Klinikum rechts der Isar der Technischen Universität München,undefined
[5] Institut für Medizinische Statistik und Epidemiologie,undefined
[6] Klinikum rechts der Isar der Technischen Universität München,undefined
[7] DZKH (German Centre for Cardiovascular Research),undefined
[8] Partner Site Munich Heart Alliance,undefined
[9] III. Medizinische Klinik,undefined
[10] Klinikum rechts der Isar der Technischen Universität München,undefined
[11] Clinic of Anesthesiology,undefined
[12] Ludwig-Maximilians-University Munich,undefined
[13] Department of Anesthesiology,undefined
[14] Center of Anesthesiology and Intensive Care Medicine,undefined
[15] University Medical Center Hamburg-Eppendorf,undefined
来源
Clinical Research in Cardiology | 2015年 / 104卷
关键词
Radial artery applanation tonometry; Arterial pressure; Hemodynamic monitoring; T-line;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:518 / 524
页数:6
相关论文
共 133 条
  • [1] Kim SH(2014)Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis Anesthesiology 120 1080-1097
  • [2] Lilot M(2014)Measurement of blood pressure Best Pract Res Clin Anaesthesiol 28 309-322
  • [3] Sidhu KS(2006)An accuracy evaluation of the T-line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients Anesth Analg 102 484-490
  • [4] Rinehart J(2008)An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotension Anaesthesia 63 307-312
  • [5] Yu Z(2012)Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry J Clin Monit Comput 26 75-83
  • [6] Canales C(2012)The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients Intensive Care Med 38 1471-1477
  • [7] Cannesson M(2013)Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device Br J Anaesth 111 185-190
  • [8] Saugel B(2013)Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome J Crit Care 28 908-912
  • [9] Dueck R(2014)Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure Br J Anaesth 112 521-528
  • [10] Wagner JY(2012)Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry J Clin Monit Comput 26 75-83