AGC of restructured multi-area multi-source hydrothermal power systems incorporating energy storage units via optimal fractional-order fuzzy PID controller

被引:0
作者
Yogendra Arya
机构
[1] Maharaja Surajmal Institute of Technology,Department of Electrical and Electronics Engineering
来源
Neural Computing and Applications | 2019年 / 31卷
关键词
Multi-area multi-source system; Fractional-order PID controller; Fuzzy PID controller; Automatic generation control; Restructured power system;
D O I
暂无
中图分类号
学科分类号
摘要
Owing to nonlinear structure and uncertain load demand characteristics, expert and intelligent automatic generation control (AGC) is inevitable for coherent operation and control of electric power system. Hence, in this paper, to mitigate the frequency and power deviations efficiently under sudden load demand conditions, a novel fractional-order fuzzy PID (FOFPID) controller is suggested in AGC of restructured multi-area multi-source hydrothermal power systems. The parameters of FOFPID controller are optimized by utilizing bacterial foraging optimization algorithm. The controller is implemented on restructured two- and three-area systems. It is observed that the advocated method shows superiority over fuzzy PID, fractional-order PID and conventional PID control schemes. Energy storage units such as redox flow batteries (RFB) which show extremely long charge–discharge life cycle and outstanding quick response to alleviate the system oscillations under disturbances have further been incorporated into the studied systems to analyze their efficacy in boosting AGC performance. Analysis of results reveals that with RFB, system transient performance improves significantly. It is also observed that the obtained results satiate the AGC requirement under different power transactions taking place in a deregulated market in the presence/absence of appropriate generation rate constraint treated for thermal and hydro plants. Finally, the robustness of the presented approach is demonstrated against the wide variations in the system parameters and initial loading condition.
引用
收藏
页码:851 / 872
页数:21
相关论文
共 121 条
  • [1] Chidambaram IA(2012)Control performance standards based load-frequency controller considering redox flow batteries coordinate with interline power flow controller J Power Sour 219 292-304
  • [2] Paramasivam B(2013)Optimized load-frequency simulation in restructured power system with redox flow batteries and interline power flow controller Int J Electr Power Energy Syst 50 9-24
  • [3] Chidambaram IA(2016)Impact of energy storage units on load frequency control of deregulated power systems Energy 97 214-228
  • [4] Paramasivam B(2016)Impact of energy storage system on load frequency control for diverse sources of interconnected power system in deregulated power environment Int J Electr Power Energy Syst 79 11-26
  • [5] Selvaraju RK(2016)Optimal AGC with redox flow batteries in multi-area restructured power systems Eng Sci Technol Int J 19 1145-1159
  • [6] Somaskandan G(2015)AGC of a multi-area power system under deregulated environment using redox flow batteries and interline power flow controller Eng Sci Technol Int J 18 555-578
  • [7] Shankar R(2017)AGC performance enrichment of multi-source hydrothermal gas power systems using new optimized FOFPID controller and redox flow batteries Energy 127 704-715
  • [8] Chatterjee K(2017)BFOA-scaled fractional order fuzzy PID controller applied to AGC of multi-area multi-source electric power generating systems Swarm Evol Comput 32 202-218
  • [9] Bhushan R(2009)Maiden application of bacterial foraging-based optimization technique in multiarea automatic generation control IEEE Trans Power Syst 24 602-609
  • [10] Arya Y(2013)BFOA based design of PID controller for two area load frequency control with nonlinearities Int J Electr Power Energy Syst 51 224-231