Spectrofluorometric determination of hesperidin by manual and flow-injection methods
被引:1
作者:
T. Pérez-Ruíz
论文数: 0引用数: 0
h-index: 0
机构:Department of Analytical Chemistry,
T. Pérez-Ruíz
C. Martínez-Lozano
论文数: 0引用数: 0
h-index: 0
机构:Department of Analytical Chemistry,
C. Martínez-Lozano
V. Tomás
论文数: 0引用数: 0
h-index: 0
机构:Department of Analytical Chemistry,
V. Tomás
J. Fenoll
论文数: 0引用数: 0
h-index: 0
机构:Department of Analytical Chemistry,
J. Fenoll
机构:
[1] Department of Analytical Chemistry,
[2] Faculty of Chemistry,undefined
[3] University of Murcia,undefined
[4] E-30071 Murcia,undefined
[5] Spain,undefined
来源:
Fresenius' Journal of Analytical Chemistry
|
1999年
/
364卷
关键词:
Aluminium;
Manifold;
Detection Limit;
Fluorescence Intensity;
Linear Relationship;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
A reliable and highly sensitive method for the determination of hesperidin is described. It involves the formation of a highly fluorescent complex between hesperidin and aluminium (III) in a micellar medium. There is a linear relationship between fluorescence intensity (λem = 496 nm, λex = 391 nm) and hesperidin concentration over the range 5 × 10–7– 2 × 10–5 mol L–1. The detection limit is 79 μg L–1. The method can easily be adapted to a flow system using a three-channel manifold, the peak height being proportional to the hesperidin concentration over the range 1 × 10–6– 1 × 10–4 mol L–1. Manual and flow-injection procedures have been successfully applied to the determination of hesperidin in orange peel and orange juice.