Modeling and numerical analysis of corona-induced vibration on high-voltage transmission line with raindrops

被引:1
|
作者
Chao Zhou
Yibing Liu
Yanping Liu
机构
[1] North China Electric Power University,School of Energy Power and Mechanical Engineering
关键词
Corona-induced vibration; Transmission line; Raindrops; Finite element method;
D O I
暂无
中图分类号
学科分类号
摘要
In rainy days, rainfall hitting high-voltage transmission lines forms raindrops that suspended to lower surface of the conductors. The suspended raindrops subjected to electric field take a cone shape, which leads to a drastic increase in local electric field and amplifies the corona discharge. Electrostatic attractive force between the conductor and the ground is partially shielded by space charge during the corona discharge. Intermittent shielding and the time lags may be the main causes of this phenomenon namely corona-induced vibration. Like any other mechanical oscillations, this kind of vibration may result in fatigue damages of conductors, failures of insulator strings and spacers. This paper is to validate a numerical model based on the finite element method and Newmark algorithm to reveal the formation mechanism of the corona-induced vibrations. According to the numerical model, the effect of rain intensity, electric field and applied voltage on vibration amplitudes and natural frequency are systematically investigated. The results agree well with experimental data available in the literature. The model and numerical analysis method enable a better comprehension of the formation mechanism of the corona-induced vibrations.
引用
收藏
页码:4575 / 4581
页数:6
相关论文
共 50 条
  • [31] Wind-rain-induced vibration test and analytical method of high-voltage transmission tower
    Li, Hong-Nan
    Tang, Shun-Yong
    Yi, Ting-Hua
    STRUCTURAL ENGINEERING AND MECHANICS, 2013, 48 (04) : 435 - 453
  • [32] Gripper vibration analysis of inspection robot during variable working flight of pre-landing on high-voltage transmission line
    Xiaodong Zhang
    Haiming Shen
    Ahmad Bala Alhassan
    Shaopeng Wang
    Haibo Xu
    Journal of Mechanical Science and Technology, 2024, 38 : 1411 - 1428
  • [33] Numerical calculation of the corona onset voltage for bundle conductors for HVDC transmission line
    Li, Zhong-Xin
    Li, Guang-Fan
    Fan, Jian-Bin
    Yin, Yu
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (01): : 11 - 17
  • [34] Corona noise model of high-voltage AC transmission lines and engineering applications
    Wu Jiuhui
    Di Zelong
    EngineeringSciences, 2013, 11 (01) : 68 - 73
  • [35] Gripper vibration analysis of inspection robot during variable working flight of pre-landing on high-voltage transmission line
    Zhang, Xiaodong
    Shen, Haiming
    Alhassan, Ahmad Bala
    Wang, Shaopeng
    Xu, Haibo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (03) : 1411 - 1428
  • [36] Research and Application of Internet of Things for High-Voltage Transmission Line
    Shen, Xin
    Cao, Min
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [37] Realization of high-voltage transmission line inspection system in GSM
    Wang, Hongwei
    Zhao, Guoqing
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (12): : 2260 - 2262
  • [38] New Approach to Improve High-Voltage Transmission Line Reliability
    Adami, J. F.
    Silveira, P. M.
    Martinez, M. L. B.
    Perez, R. C.
    Dallbello, A. C.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1515 - 1520
  • [39] HYBRID TRANSMISSION-LINE GREINACHER HIGH-VOLTAGE GENERATOR
    BRAUTTI, G
    RAINO, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (2-3): : 598 - 599
  • [40] CURRENT LOAD IN A HIGH-VOLTAGE POWER TRANSMISSION-LINE
    LIN, SH
    ELECTRIC POWER SYSTEMS RESEARCH, 1991, 21 (03) : 181 - 185