Modeling and numerical analysis of corona-induced vibration on high-voltage transmission line with raindrops

被引:1
|
作者
Chao Zhou
Yibing Liu
Yanping Liu
机构
[1] North China Electric Power University,School of Energy Power and Mechanical Engineering
关键词
Corona-induced vibration; Transmission line; Raindrops; Finite element method;
D O I
暂无
中图分类号
学科分类号
摘要
In rainy days, rainfall hitting high-voltage transmission lines forms raindrops that suspended to lower surface of the conductors. The suspended raindrops subjected to electric field take a cone shape, which leads to a drastic increase in local electric field and amplifies the corona discharge. Electrostatic attractive force between the conductor and the ground is partially shielded by space charge during the corona discharge. Intermittent shielding and the time lags may be the main causes of this phenomenon namely corona-induced vibration. Like any other mechanical oscillations, this kind of vibration may result in fatigue damages of conductors, failures of insulator strings and spacers. This paper is to validate a numerical model based on the finite element method and Newmark algorithm to reveal the formation mechanism of the corona-induced vibrations. According to the numerical model, the effect of rain intensity, electric field and applied voltage on vibration amplitudes and natural frequency are systematically investigated. The results agree well with experimental data available in the literature. The model and numerical analysis method enable a better comprehension of the formation mechanism of the corona-induced vibrations.
引用
收藏
页码:4575 / 4581
页数:6
相关论文
共 50 条
  • [1] Modeling and numerical analysis of corona-induced vibration on high-voltage transmission line with raindrops
    Zhou, Chao
    Liu, Yibing
    Liu, Yanping
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (11) : 4575 - 4581
  • [2] EXPERIMENTAL INVESTIGATIONS OF CORONA-INDUCED VIBRATION ON HIGH-VOLTAGE CONDUCTORS WITH DIFFERENT TYPES OF SUPPORTS
    PHAN, LC
    ADACHI, T
    ALLAIRE, MA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 1975 - 1985
  • [3] Corona characteristics of high-voltage transmission line
    Xie, Shuyong
    Wang, Yun
    Gaoya Dianqi/High Voltage Apparatus, 1996, 32 (05): : 20 - 22
  • [4] Numerical Analysis of the Induced Corona Vibrations on High-Voltage Transmission Lines Affected by Rainfall
    Brahami, M.
    Gourbi, A.
    Tilmatine, A.
    Dascalescu, L.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 617 - 624
  • [5] Mechanism analysis of rain-wind induced vibration on high-voltage transmission line
    Li, Li
    Zhou, Chao
    Liu, Yanping
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON STRUCTURAL, MECHANICAL AND MATERIAL ENGINEERING (ICSMME 2015), 2016, 19 : 133 - 136
  • [6] ON THE ROLE OF THE SPACE-CHARGE PRODUCED BY HANGING WATER DROPS IN THE MECHANISM OF THE CORONA-INDUCED VIBRATION OF HIGH-VOLTAGE CONDUCTORS
    FARZANEH, M
    PHAN, LC
    AI, B
    JOURNAL OF ELECTROSTATICS, 1985, 17 (03) : 235 - 244
  • [7] A LABORATORY STUDY OF CORONA-INDUCED VIBRATION OF HIGH-VOLTAGE SMOOTH ALUMINUM DC CONDUCTORS IN A MASS-SPRING CONFIGURATION
    ADACHI, T
    PHAN, LC
    JOURNAL OF ELECTROSTATICS, 1981, 9 (03) : 273 - 288
  • [8] Mechanism and modeling of rain-wind induced in-plane vibration on high-voltage transmission line
    Zhou, Chao
    Liu, Yan-ping
    Song, Yu-wang
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (04) : 1175 - 1180
  • [9] Mechanism and modeling of rain-wind induced in-plane vibration on high-voltage transmission line
    Chao Zhou
    Yan-ping Liu
    Yu-wang Song
    Journal of Mechanical Science and Technology, 2014, 28 : 1175 - 1180
  • [10] Mechanism and characteristic of rain-induced vibration on high-voltage transmission line
    Chao Zhou
    Yibing Liu
    Xiaoming Rui
    Journal of Mechanical Science and Technology, 2012, 26 : 2505 - 2510