Aging evaluation for transformer oil-immersed cellulose insulation by using frequency dependent dielectric modulus technique

被引:0
|
作者
Jiefeng Liu
Heng Zhang
Xianhao Fan
Yiyi Zhang
Chaohai Zhang
机构
[1] Guangxi University,School of Electrical Engineering
来源
Cellulose | 2021年 / 28卷
关键词
Transformer cellulose insulation; Frequency domain spectroscopy (FDS); Aging evaluation; Frequency dependent dielectric modulus (FDDM);
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2387 / 2401
页数:14
相关论文
共 50 条
  • [41] Influence of insulation paper on the hot spot temperature of oil-immersed transformer winding
    Luo, Chuan
    Zhao, Zhen-Gang
    Wang, Yu-Yuan
    Liang, Ke
    Zhang, Jia-Hong
    Li, Ying-Na
    Li, Chuan
    MODERN PHYSICS LETTERS B, 2021, 35 (28):
  • [42] Oil-paper Insulation Characteristic and Maintenance Measures of Oil-immersed Transformer in Cold Environment
    Sun, Jiantao
    Zhang, Shuqi
    Xu, Zhengyu
    Wu, Chao
    Yu, Xinru
    Qiu, Yuzhou
    Gao, Ziwei
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,
  • [43] Insulation Condition Diagnosis of Oil-Immersed Paper Insulation Based on Non-linear Frequency-Domain Dielectric Response
    Zhang, Daning
    Yun, Hao
    Zhan, Jiangyang
    Sun, Xiang
    He, Wenlin
    Niu, Chaobin
    Mu, Haibao
    Zhang, Guan-jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 1980 - 1988
  • [44] Prediction of Dissolved Alcohol Concentrations in Transformer Oil and Aging Evaluation of Cellulose Insulation
    Zhang, Heng
    Zhang, Yuan
    Jiang, Zaijun
    Fan, Xianhao
    Li, Wen
    Liu, Chuying
    Zhang, Enze
    Wu, Thomas
    Liu, Jiefeng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) : 1238 - 1245
  • [45] Dielectric Performance of Magneto-Nanofluids for Advancing Oil-Immersed Power Transformer
    Hussain, Md Rashid
    Khan, Qasim
    Khan, Asfar Ali
    Refaat, Shady S.
    Abu-Rub, Haitham
    IEEE ACCESS, 2020, 8 (08): : 163316 - 163328
  • [46] Inversion of Oil-Immersed Paper Resistivity in Transformer Based on Dielectric Loss Factor
    Ruan, Jiangjun
    Xie, Yiming
    Jin, Shuo
    Shi, Yu
    Tian, Yu
    Deng, Yongqing
    IEEE ACCESS, 2019, 7 : 44050 - 44058
  • [47] Fractional transmission line model of oil-immersed transformer windings considering the frequency-dependent parameters
    Liang, Guishu
    Gao, Shiqiang
    Wang, Yanchao
    Zang, Ying
    Liu, Xin
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (05) : 1154 - 1161
  • [48] Diagnosis for oil-immersed insulation using partial discharge due to bubbles in oil
    Shiota, H
    Muto, H
    Fujii, H
    Hosokawa, N
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1120 - 1123
  • [49] A comprehensive evaluation method for moisture and aging state of oil-immersed paper bushings based on dielectric modulus and K-nearest neighbor algorithm
    Liang, Zhengping
    Sun, Yongbin
    Cheng, Hao
    Zhang, Na
    Li, Bo
    Liu, Yang
    Fang, Yan
    Zhang, Yiyi
    FRONTIERS IN ENERGY RESEARCH, 2024, 11
  • [50] Influence of Measurement Parameters on Frequency Response Analysis Diagnosis of Oil-Immersed Transformer
    Sano, Takahiro
    Miyagi, Katsunori
    ELECTRICAL ENGINEERING IN JAPAN, 2014, 186 (01) : 18 - 25