Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions

被引:0
|
作者
Xiuyu Wang
Peng Wang
Heng Zhang
Xian Wang
Jie Shi
Shudong Hu
机构
[1] Jiangnan University,Department of Radiology, Affiliated Hospital
[2] Jiangsu University,Department of Radiology, Affiliated Renmin Hospital
[3] GE Healthcare,undefined
来源
Japanese Journal of Radiology | 2024年 / 42卷
关键词
Thyroid; Magnetic resonance imaging; Diffusion-weighted imaging; Multiplexed sensitivity encoding;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:268 / 275
页数:7
相关论文
共 50 条
  • [31] Characterization of focal liver lesions with diffusion-weighted echo-planar imaging
    Laghi, A
    Pavone, P
    Catalano, C
    Panebianco, V
    Fabiano, S
    Baeli, I
    Passariello, R
    HEPATOLOGY, 1999, 30 (04) : 282A - 282A
  • [32] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [33] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Kim, Hyungjin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Jang, Jin-Young
    Kim, Sun-Whe
    Ryu, Ji Kon
    Kannengiesser, Stephan
    Ha, Joon Koo
    Choi, Byung Ihn
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1216 - 1225
  • [34] Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil
    Amano, Y
    Kumazaki, T
    Ishihara, M
    ACTA RADIOLOGICA, 1998, 39 (04) : 440 - 442
  • [35] Single-shot velocity mapping by rewinding of velocity encoding with Echo-Planar Imaging
    Serial, Maria R.
    Silletta, Emilia, V
    Perlo, Josefina
    Giovacchini, Juan P.
    Velasco, Manuel, I
    Bluemich, Bernhard
    Danieli, Ernesto D.
    Casanova, Federico
    Acosta, Rodolfo H.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 307
  • [36] Single-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma
    De Foer, B.
    Vercruysse, J. -P.
    Pilet, B.
    Michiels, J.
    Vertriest, R.
    Pouillon, M.
    Somers, T.
    Caselman, J. W.
    Offeciers, E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (07) : 1480 - 1482
  • [37] Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    Bruegel, Melanie
    Holzapfel, Konstantin
    Gaa, Jochen
    Woertler, Klaus
    Waldt, Simone
    Kiefer, Berthold
    Stemmer, Alto
    Ganter, Carl
    Rummeny, Ernst J.
    EUROPEAN RADIOLOGY, 2008, 18 (03) : 477 - 485
  • [38] Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    Melanie Bruegel
    Konstantin Holzapfel
    Jochen Gaa
    Klaus Woertler
    Simone Waldt
    Berthold Kiefer
    Alto Stemmer
    Carl Ganter
    Ernst J. Rummeny
    European Radiology, 2008, 18 : 477 - 485
  • [39] Diffusion-Weighted Imaging with Dual-Echo Echo-Planar Imaging for Better Sensitivity to Acute Stroke
    Holdsworth, S. J.
    Yeom, K. W.
    Antonucci, M. U.
    Andre, J. B.
    Rosenberg, J.
    Aksoy, M.
    Straka, M.
    Fischbein, N. J.
    Bammer, R.
    Moseley, M. E.
    Zaharchuk, G.
    Skare, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1293 - 1302
  • [40] Comparison of Readout-Segmented Echo-Planar Imaging (EPI) and Single-Shot EPI in Clinical Application of Diffusion-Weighted Imaging of the Pediatric Brain
    Yeom, Kristen W.
    Holdsworth, Samantha J.
    Van, Anh T.
    Iv, Michael
    Skare, Stefan
    Lober, Robert M.
    Bammer, Roland