Mathematical modeling of blood flow through a stenosed artery under body acceleration

被引:0
作者
Ahmad Reza Haghighi
Soraya Asadi Chalak
机构
[1] Urmia University of Technology,Department of Mathematics
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2017年 / 39卷
关键词
Finite difference method; Body accleration; Tapered artery; Sisko fluid; 92B05; 92A08;
D O I
暂无
中图分类号
学科分类号
摘要
In this research, a mathematical model of pulsating blood flow is numerically simulated in a stenotic artery. The Sisko fluid model has been used to describe the non-Newtonian rheology of blood. Vessels are assumed to be elastic and so their geometry is time-dependent. To simulate a more real human body, the stenoses are assumed to be tapered. By applying radial coordinate transformation, elastic vessel is transformed to rectangular shape vessel. Navier–Stokes equations of blood flow are solved using the finite difference method, considering the pressure gradient and body acceleration. Dynamic characteristics, such as blood flow velocity, volumetric flow rate and resistance to flow rate are obtained and the impact of body acceleration parameters on them is discussed. The results of the simulation are in good agreement with existing results .
引用
收藏
页码:2487 / 2494
页数:7
相关论文
共 81 条
[1]  
Mortazavinia Z(2012)Effects of renal artery stenosis on realistic model of abdominal aorta and renal arteries incorporating fluid–structure interaction and pulsatile non-Newtonian blood flow Appl Math Mech Eng Ed 33 165-176
[2]  
Zare A(2010)The effect of body acceleration on two dimensional flow of Casson fluid through an artery with asymmetric stenosis Open Transp Phenom J 2 55-68
[3]  
Mehdizadeh A(2012)Mathematical model of the impact of pressure drop on human body Selcuk J Appl Math 13 35-40
[4]  
Shaw S(1996)Pulsatile flow of non-Newtonian fluids through arterial stenoses J Biomech 29 899-908
[5]  
Zare P(2004)Unsteady flow of a two-layer blood stream past a tapered flexible artery under stenotic conditions Comput Methods Appl Math 4 391-409
[6]  
Pradhan S(2011)Two-phase non-linear model for blood flow in asymmetric and axisymmetric stenosed arteries Int J Non-linear Mech 46 296-305
[7]  
Haghighi AR(2011)FDM analysis for MHD flow of a non-Newtonian fluid for blood flow in stenosed arteries J Mech Sci Technol 25 2573-2581
[8]  
Tu C(2016)A non-Newtonian model of pulsatile blood flow through elastic artery with overlapping stenosis Modares Mech Eng 16 232-238
[9]  
Deville M(1998)An analytical estimate of the flow-field in a porous stenotic artery subject to body acceleration Int J Eng Sci 36 1083-1102
[10]  
Chakravarty S(2015)Numerical study of unsteady blood flow through a vessel using Sisko model Int J Eng Sci Technol 19 538-547