Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

被引:0
|
作者
K. Hata
K. Fukuda
S. Masuzaki
机构
[1] Kobe University,Graduate School of Marine Sciences
[2] National Institute for Fusion Science,undefined
来源
Heat and Mass Transfer | 2018年 / 54卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods (Q = Q0exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities (G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures (Tin = 285.88 to 299.09 K), and inlet pressures (Pin = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δT = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k–ε turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔTL [ = Ts,av- TL, TL = (Tin + Tout)/2] considered in this study. The theoretical values of the local surface temperature Ts, local average liquid temperature Tf,av, and local liquid pressure drop ΔPx were found to be within almost 15% of the corresponding experimental ones. The thickness of the conductive sub-layer δCSL and the nondimensional thickness of the conductive sub-layer y+CSL on the circular tubes with various twisted-tape inserts were determined on the basis of numerical solutions for the swirl velocities usw ranging from 5.23 to 21.18 m/s. Correlations between the conductive sub-layer thickness δCSL and the nondimensional thickness of the conductive sub-layer y+CSL for twisted-tape-induced swirl-flow heat transfer in a vertical circular tube were derived.
引用
收藏
页码:963 / 983
页数:20
相关论文
共 50 条
  • [41] Numerical Study on Enhanced Heat Transfer by Twisted Tape Inserts inside Tubes
    Zhu, J. D.
    Chen, H.
    PRESSURE VESSEL TECHNOLOGY: PREPARING FOR THE FUTURE, 2015, 130 : 256 - 262
  • [42] Friction and heat transfer characteristics of laminar swirl flow through a circular tube fitted with regularly spaced twisted-tape elements
    Saha, SK
    Dutta, A
    Dhal, SK
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) : 4211 - 4223
  • [43] Performance evaluation of twisted-tape insert induced swirl flow in a laminar thermally developing heat exchanger
    Lim, Kwok Yoong
    Hung, Yew Mun
    Tan, Boon Thong
    APPLIED THERMAL ENGINEERING, 2017, 121 : 652 - 661
  • [44] Heat conveyance and application in enhancing heat transfer with heat exchanger tubes with twisted-tape insert
    Kong, Songtao
    Dong, Qiwu
    Liu, Minshan
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (04): : 83 - 87
  • [45] Transient Critical Heat Fluxes of Subcooled Water Flow Boiling in SUS304-Circular Tubes With Various Twisted-Tape Inserts (Influence of Twist Ratio)
    Hata, Koichi
    Fukuda, Katsuya
    Masuzaki, Suguru
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2014, 6 (03)
  • [46] A Numerical Study of the Flow and Heat Transfer Characteristics of Outward Convex Corrugated Tubes With Twisted-Tape Insert
    Yang, Longbin
    Han, Huaizhi
    Li, Yanjun
    Li, Xiaoming
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (02):
  • [47] Critical heat flux and pressure drop of subcooled flow boiling in small-diameter tubes with twisted-tape inserts
    Tong, W
    Bergles, AE
    Jensen, MK
    JOURNAL OF ENHANCED HEAT TRANSFER, 1996, 3 (02) : 95 - 108
  • [48] Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts
    Liao, Q
    Xin, MD
    CHEMICAL ENGINEERING JOURNAL, 2000, 78 (2-3) : 95 - 105
  • [49] Experimental study of the effect of twisted-tape inserts on flow boiling heat transfer enhancement and pressure drop penalty
    Mogaji, Taye Stephen
    Kanizawa, Fabio Toshio
    Bandarra Filho, Enio Pedone
    Ribatski, Gherhardt
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (02): : 504 - 515
  • [50] Numerical simulation of fluid flow and heat transfer in tube inserting twisted-tape
    Sun, Dongliang
    Wang, Liangbi
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2004, 55 (09): : 1422 - 1427