Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

被引:0
|
作者
K. Hata
K. Fukuda
S. Masuzaki
机构
[1] Kobe University,Graduate School of Marine Sciences
[2] National Institute for Fusion Science,undefined
来源
Heat and Mass Transfer | 2018年 / 54卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods (Q = Q0exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities (G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures (Tin = 285.88 to 299.09 K), and inlet pressures (Pin = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δT = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k–ε turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔTL [ = Ts,av- TL, TL = (Tin + Tout)/2] considered in this study. The theoretical values of the local surface temperature Ts, local average liquid temperature Tf,av, and local liquid pressure drop ΔPx were found to be within almost 15% of the corresponding experimental ones. The thickness of the conductive sub-layer δCSL and the nondimensional thickness of the conductive sub-layer y+CSL on the circular tubes with various twisted-tape inserts were determined on the basis of numerical solutions for the swirl velocities usw ranging from 5.23 to 21.18 m/s. Correlations between the conductive sub-layer thickness δCSL and the nondimensional thickness of the conductive sub-layer y+CSL for twisted-tape-induced swirl-flow heat transfer in a vertical circular tube were derived.
引用
收藏
页码:963 / 983
页数:20
相关论文
共 50 条
  • [31] HEAT TRANSFER AND HYDRAULIC RESISTANCE OF FORCED CONVECTION IN TUBES WITH TWISTED-TAPE INSERTS AND DIFFERENT INLET CONDITIONS
    Yakovlev, Anatoly
    Tarasevich, Stanislav
    JOURNAL OF ENHANCED HEAT TRANSFER, 2014, 21 (2-3) : 183 - 194
  • [32] A review of flow boiling heat transfer with twisted tape inserts
    Shatto, DP
    Peterson, GP
    JOURNAL OF ENHANCED HEAT TRANSFER, 1996, 3 (04) : 233 - 257
  • [33] HYDRODYNAMICS AND HEAT TRANSFER IN TUBES WITH SMOOTH AND RIBBED TWISTED TAPE INSERTS
    Yakovlev, A. B.
    Tarasevich, S. E.
    Giniyatullin, A. A.
    Shishkin, A. V.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2013, 20 (06) : 511 - 518
  • [34] Analysis of heat transfer characteristics with triangular cut twisted tape (TCTT) and circular cut twisted tape (CCTT) inserts
    Sivakumar, K.
    Rajan, K.
    Mohankumar, T.
    Naveenchnadran, P.
    MATERIALS TODAY-PROCEEDINGS, 2020, 22 : 375 - 382
  • [35] Heat Transfer in a Vertical Tube with Twisted Tape Swirl Generators.
    Filipiak, Edward
    Zeszyty Naukowe Politechniki Lodzkiej Mechanika, 1980, (60): : 41 - 53
  • [36] EXPERIMENTAL INVESTIGATION FOR FLUID-FLOW AND HEAT-TRANSFER IN A ROTATING TUBE WITH TWISTED-TAPE INSERTS
    RAO, MM
    SASTRI, VMK
    HEAT TRANSFER ENGINEERING, 1995, 16 (02) : 19 - 28
  • [37] SATURATED FORCED-CONVECTIVE BOILING HEAT-TRANSFER WITH TWISTED-TAPE INSERTS
    JENSEN, MK
    BENSLER, HP
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1986, 108 (01): : 93 - 99
  • [38] Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow
    Al-Fahed, S
    Chamra, LM
    Chakroun, W
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 18 (04) : 323 - 333
  • [39] Heat transfer enhancement by multiple swirling impinging jets with twisted-tape swirl generators
    Nuntadusit, C.
    Wae-hayee, M.
    Bunyajitradulya, A.
    Eiamsa-ard, S.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2012, 39 (01) : 102 - 107
  • [40] SATURATED FORCED-CONVECTIVE BOILING HEAT TRANSFER WITH TWISTED-TAPE INSERTS.
    Jensen, M.K.
    Bensler, H.P.
    Journal of Heat Transfer, 1986, 108 (01): : 93 - 99