Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry

被引:0
作者
Rebecca Moylan
Trent Aland
Tanya Kairn
机构
[1] Premion,Science and Engineering Faculty
[2] Queensland University of Technology,undefined
来源
Australasian Physical & Engineering Sciences in Medicine | 2013年 / 36卷
关键词
EBT2; EBT3; Gafchromic film; In vivo dosimetry; Radiotherapy;
D O I
暂无
中图分类号
学科分类号
摘要
Radiochromic film has the potential to provide accurate in vivo dosimetry measurements. However, it is not known whether small film pieces can still provide accurate dosimetric results. The use of small film pieces is of particular interest in regions of interest (ROIs) such as the eye, or where the patient’s contour changes rapidly. This study examines the dosimetric accuracy of Gafchromic EBT2 and EBT3 models of radiochromic film and its dependence on film size, ROI size, and height above the scan bed for 6 MV photons and 9 MeV electrons. Films cut to sizes of 5.0 × 5.0, 10.0 × 10.0, 20.0 × 20.0, and 40.0 × 40.0 mm2 were tested and it was found that there was no increase in uncertainty of dose when even the smallest film sizes were used. For a film 5.0 × 5.0 mm2, ROIs of 1.4 × 1.4, 2.1 × 2.1 and 3.5 × 3.5 mm2 were tested and it was found that the ROI size of 2.1 × 2.1 mm2 was the most accurate. The standard deviation of the EBT3 placed on the glass (2.1 %) was larger than the standard deviation of the EBT3 film raised above the glass (1.2 %), therefore it is recommended that film is scanned raised above the scan bed. The general dosimetric performance of EBT3 was comparable to EBT2. We conclude that film pieces as small as 5.0 × 5.0 mm2 could be used for the purpose of in vivo dosimetry of radiotherapy treatments.
引用
收藏
页码:331 / 337
页数:6
相关论文
共 112 条
[1]  
Kutcher GJ(1994)Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40 Med Phys 21 581-618
[2]  
Coia L(1997)Monitor unit calculation for high energy photon beams, first edition Booklet 3 p121-p124
[3]  
Gillin M(2009)Optimizing the dynamic range extension of a radiochromic film dosimetry system Med Phys 36 429-437
[4]  
Hanson WF(2012)Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams Med Phys 39 5257-5262
[5]  
Leibel S(2010)Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film Med Phys 37 1110-1117
[6]  
Morton RJ(2010)Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies Med Phys 37 1942-1947
[7]  
Palta JR(2010)Investigation of energy dependence of EBT and EBT-2 Gafchromic film Med Phys 37 571-576
[8]  
Purdy JA(2010)Energy response of the new EBT2 radiochromic film to X-ray radiation Radia Meas 45 836-839
[9]  
Reinstein LE(2012)Energy dependence of the new Gafchromic EBT3 film: dose response curves for 50 kV, 6 and 15 MV X-ray beams Int J Med Phys Clin Eng Radiat Oncol 1 60-65
[10]  
Svensson GK(2012)EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities Med Phys 39 912-921