Development of a control system for the 14.5 GHz ECR ion source

被引:0
作者
Jeong-Hwan Kim
Won-Taek Hwang
Dong-Wook Park
Hong-Suk Chang
Tae-Keun Yang
Kun-Uk Kang
Se-Duk Chang
Chang-Hyeuk Kim
Hwa-Ryun Lee
Hyun-Yong Kim
Geun-Beom Kim
机构
[1] Korea Institute of Radiological and Medical Science,Korea Heavy Ion Medical Accelerator
来源
Journal of the Korean Physical Society | 2013年 / 63卷
关键词
KHIMA; ECR ion source; Control system; Electric control cabinet; Main control program;
D O I
暂无
中图分类号
学科分类号
摘要
A control system of the 14.5 GHz electron cyclotron resonance (ECR) ion source has been designed and developed in KHIMA(Korea Heavy Ion Medical Accelerator) project which will use C6+ ions for heavy ion therapy. Production of the selected ion beam in stable operation with safety is a development goal with flexibility by easy access and modification which are necessary during development process with an accelerator. The control system of the ECR ion source system consists of electric control cabinet (ECC) as hardware and main control program (MCP) as software, respectively. ECC developed to manage power and control flow with electric components and controllers controls the injection system, RF system, high voltage & extraction system, analyzing system, vacuum system, cooling system, diagnosis system and safety system. MCP is the supervisory program developed for effective automation and data acquisition by LabVIEW-based graphical programming. The isolated network from a control computer to ECC and bleeder resistors in a steel plate box composed by the simulation result for high voltage power supplies increase reliability and safety. The performance of the developed control system has been verified successfully by beam extraction of C4+ ion from CO2 as main gas and He as support gas through an analyzing magnet and a faraday cup with the acquired spectrum at the control system. After optimization with C4+ ions, measurement of characteristics of C6+ ions including emittance of the ion beam will be planned early 2013. Also, quantity of C6+ ions in the same charge to mass ratio will be estimated by using 13CO2 as main gas and He as support gas.
引用
收藏
页码:1316 / 1321
页数:5
相关论文
共 23 条
[1]  
Bliman S(1972)undefined IEEE Trans. Nucl. Sci. NS-19 200-undefined
[2]  
Geller R(2008)undefined Rev. Sci. Instrum. 79 02C505-undefined
[3]  
Hess W(2010)undefined Rev. Mod. Phys. 82 383-undefined
[4]  
Jacqot B(2011)undefined J. Korean Phys. Soc. 58 771-undefined
[5]  
Jacquot C(2003)undefined NUKLEONICA 48 S93-undefined
[6]  
Tinschert K(undefined)undefined undefined undefined undefined-undefined
[7]  
Iannucci R(undefined)undefined undefined undefined undefined-undefined
[8]  
Lang R(undefined)undefined undefined undefined undefined-undefined
[9]  
Schardt D(undefined)undefined undefined undefined undefined-undefined
[10]  
Elsässer T(undefined)undefined undefined undefined undefined-undefined