Voltammetric determination of iodide by use of an interdigitated microelectrode array

被引:0
作者
Peter Tomčík
Dušan Bustin
机构
[1] Department of Analytical Chemistry,
[2] Slovak University of Technology,undefined
[3] Radlinského 9,undefined
[4] 812 37 Bratislava,undefined
[5] Slovak Republic,undefined
来源
Fresenius' Journal of Analytical Chemistry | 2001年 / 371卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An interdigitated microelectrode array (IDA) sensor has been applied to the determination of iodide in mineral water. It is based on reversible charge transfer in the redox system I2/2I– at a platinum microelectrode. The analytical signal from the IDA system was obtained by use of a bipotentiostat in dual mode. One segment of the IDA (generator) was polarized to the limiting current for oxidation of iodide to iodine in 0.1 mol L–1 HClO4. The second segment (collector) was fixed at a potential value corresponding to the limiting current of iodine reduction. The geometrical arrangement of the IDA enables this transfer with high efficiency. Because the diffusion layer of both segments overlaps the iodide produced on the collector, the iodide diffuses back to the generator where it is reoxidized. Therefore, redox cycling will enhance the voltammetric signal of the IDA. The signal obtained with a vertically separated IDA was 20 times higher than that in the single mode. Because multiplication of the signal reduces the detection and determination limits, direct voltammetric determination of iodide in mineral water is possible.
引用
收藏
页码:562 / 564
页数:2
相关论文
共 50 条
[21]   Titration of As(III) with electrogenerated iodine in the diffusion layer of an interdigitated microelectrode array [J].
Tomcik, P ;
Jursa, S ;
Mesaros, S ;
Bustin, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 423 (1-2) :115-118
[22]   Voltammetric approach to trace iodide determination [J].
Sharma, P ;
Sharma, R .
BULLETIN OF ELECTROCHEMISTRY, 2004, 20 (06) :273-276
[23]   VOLTAMMETRIC DETERMINATION OF SELENIUM - COMPARISON OF ELECTRODE AND MICROELECTRODE GEOMETRIES [J].
BOWYER, WJ ;
HREHOCIK, ME ;
LUNDGREN, JS .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 :65-ANYL
[24]   Microanalytical Determination of Formaldehyde by Direct Titration with Hydroxylamine Using Interdigitated Microelectrode Array Biamperometric End-Point Indicator [J].
Peter Tomčík ;
Lea Mrafková ;
Dušan Bustin .
Microchimica Acta, 2003, 141 :69-72
[25]   Voltammetric study of vitamin K3 at interdigitated array microelectrodes [J].
Liu, ZM ;
Li, J ;
You, TY ;
Yang, XR ;
Wang, EK .
ELECTROANALYSIS, 1999, 11 (01) :53-58
[26]   Microanalytical determination of formaldehyde by direct titration with hydroxylamine using interdigitated microelectrode array biamperometric end-point indicator [J].
Tomcik, P ;
Mrafková, L ;
Bustin, D .
MICROCHIMICA ACTA, 2003, 141 (1-2) :69-72
[27]   Computer Aided Modelling of an Interdigitated Microelectrode Array Impedance Biosensor for the Detection of Bacteria [J].
Webster, M. S. ;
Timoshkin, I. V. ;
MacGregor, S. J. ;
Mattey, M. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (05) :1356-1363
[28]   Microfluidic chip with interdigitated ultra-microelectrode array for total phosphorus detection [J].
Bai, Yin ;
Tong, Jianhua ;
Sun, Jizhou ;
Li, Yang ;
Bian, Chao ;
Xia, Shanhong .
MICRO & NANO LETTERS, 2014, 9 (12) :862-865
[29]   Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect [J].
Yuan, Quan ;
Yang, Kai ;
Wu, Jie .
MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (1-2) :167-178
[30]   Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect [J].
Quan Yuan ;
Kai Yang ;
Jie Wu .
Microfluidics and Nanofluidics, 2014, 16 :167-178