Voltammetric determination of iodide by use of an interdigitated microelectrode array

被引:0
|
作者
Peter Tomčík
Dušan Bustin
机构
[1] Department of Analytical Chemistry,
[2] Slovak University of Technology,undefined
[3] Radlinského 9,undefined
[4] 812 37 Bratislava,undefined
[5] Slovak Republic,undefined
来源
Fresenius' Journal of Analytical Chemistry | 2001年 / 371卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An interdigitated microelectrode array (IDA) sensor has been applied to the determination of iodide in mineral water. It is based on reversible charge transfer in the redox system I2/2I– at a platinum microelectrode. The analytical signal from the IDA system was obtained by use of a bipotentiostat in dual mode. One segment of the IDA (generator) was polarized to the limiting current for oxidation of iodide to iodine in 0.1 mol L–1 HClO4. The second segment (collector) was fixed at a potential value corresponding to the limiting current of iodine reduction. The geometrical arrangement of the IDA enables this transfer with high efficiency. Because the diffusion layer of both segments overlaps the iodide produced on the collector, the iodide diffuses back to the generator where it is reoxidized. Therefore, redox cycling will enhance the voltammetric signal of the IDA. The signal obtained with a vertically separated IDA was 20 times higher than that in the single mode. Because multiplication of the signal reduces the detection and determination limits, direct voltammetric determination of iodide in mineral water is possible.
引用
收藏
页码:562 / 564
页数:2
相关论文
共 50 条
  • [1] Voltammetric determination of iodide by use of an interdigitated microelectrode array
    Tomcík, P
    Bustin, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 562 - 564
  • [2] Determination of tetramethylthiuram disulfide on an interdigitated microelectrode array
    Tomcík, P
    Krajcíková, M
    Bustin, D
    Skacáni, I
    ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (04) : 191 - 194
  • [3] Indirect voltammetric detection of fluoride ions in toothpaste on a comb-shaped interdigitated microelectrode array
    Cernanska, Monika
    Tomcik, Peter
    Janosikova, Zuzana
    Rievaj, Miroslav
    Bustin, Dusan
    TALANTA, 2011, 83 (05) : 1472 - 1475
  • [4] Voltammetric detection of titanium(IV) on interdigitated microelectrode array utilising its catalytically enhanced current with hydroxylamine
    Tomcik, Peter
    Jencusova, Pavlina
    Krajcikova, Monika
    Bustin, Dusan
    Manova, Alena
    Cakrt, Miroslav
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 593 (1-2) : 167 - 171
  • [5] Glucose Sensing Based on Interdigitated Array Microelectrode
    Peng Jin
    Akira Yamaguchi
    Fumika Asarioi
    Shigeki Matsuo
    Jiubin Tan
    Hiroaki Misawa
    Analytical Sciences, 2001, 17 : 841 - 846
  • [6] Glucose sensing based on interdigitated array microelectrode
    Jin, P
    Yamaguchi, A
    Oi, FA
    Matsuo, S
    Tan, JB
    Misawa, H
    ANALYTICAL SCIENCES, 2001, 17 (07) : 841 - 846
  • [7] Determination of pharmaceutical dosage forms via diffusion layer titration at an interdigitated microelectrode array
    Tomcík, P
    Krajcíková, M
    Bustin, D
    TALANTA, 2001, 55 (06) : 1065 - 1070
  • [8] Calibrationless determination of electroactive species using chronoamperograms at collector segment of interdigitated microelectrode array
    P. Jenčušová
    P. Tomčík
    D. Bustin
    M. Rievaj
    Z. Dovalovská
    Chemical Papers, 2006, 60 : 173 - 178
  • [9] Calibrationless determination of electroactive species using chronoamperograms at collector segment of interdigitated microelectrode array
    Jencusova, P.
    Tomcik, P.
    Bustin, D.
    Rievaj, M.
    Dovalovska, Z.
    CHEMICAL PAPERS, 2006, 60 (03) : 173 - 178
  • [10] Calibrationless determination of potassium hexacyanoferrate(II) and hexaammineruthenium(III) chloride at the interdigitated microelectrode array (IDA)
    Tomcik, P
    Skalicanová, A
    Bustin, D
    Rievaj, M
    CHEMIA ANALITYCZNA, 2004, 49 (01): : 41 - 49