Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as “in”, “out” or “questionable”. On average, 88% and 92% of the screws were classified as “in” by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.
引用
收藏
页码:531 / 536
页数:5
相关论文
共 138 条
[1]  
Abumi K(1999)One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems J Neurosurg 90 19-26
[2]  
Kaneda K(2000)Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique J Spinal Disord 13 496-500
[3]  
Shono Y(2003)Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications Spine 28 91-97
[4]  
Fujiya M(2000)In vivo pedicle screw placement: image-guided virtual vision J Spinal Disord 13 225-229
[5]  
Boachie-Adjei O(1996)Accuracy of pedicle screw placement in lumbar vertebrae Spine 21 1320-1324
[6]  
Girardi FP(2004)Accuracy of computed tomography in assessing thoracic pedicle screw malposition J Spinal Disord Tech 17 367-371
[7]  
Bansal M(1997)Reliability of roentgenogram evaluation of pedicle screw position Spine 22 1249-1252
[8]  
Rawlins BA(1999)The placement of lumbar pedicle screws using computerised stereotactic guidance J Bone Joint Surg Br 81 825-829
[9]  
Carbone JJ(2000)Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis Eur Spine J 9 191-197
[10]  
Tortolani PJ(2004)Thoracic pedicle screws: postoperative computerized tomography scanning assessment J Neurosurg 100 325-331