Validation, using a chemometric approach, of gas chromatography–inductively coupled plasma–atomic emission spectrometry (GC–ICP–AES) for organotin determination

被引:1
作者
Sandrine Aguerre
Christophe Pécheyran
Gaëtane Lespes
机构
[1] UMR 5034 CNRS Université de Pau et des Pays de l'Adour,Laboratoire de Chimie Analytique Bio
来源
Analytical and Bioanalytical Chemistry | 2003年 / 376卷
关键词
GC; ICP–AES; Experimental design; Organotin; Speciation;
D O I
暂无
中图分类号
学科分类号
摘要
The coupling between gas chromatography (GC) and inductively coupled plasma–atomic emission spectrometry (ICP–AES) has been optimised using experimental designs. Four factors were considered in order to assist the crucial part of the coupling which is the analytes passing through the transfer line. The methodological approach based on the planning of fractional designs is described and justified according to an optimal experimentation. Then, the GC–ICP–AES-based method has been validated by means of statistical tests performed on calibration curves and evaluation of accuracy, precision and limits of detection (LOD), according to ISO standards and IUPAC recommendations. The absolute LOD are found to be quite similar to those obtained using flame photometer. Relative LOD ranged between 20 and 80 ng (Sn) L−1 after liquid–liquid extraction of the analytes. When solid phase micro-extraction (SPME) is used, LOD are sub 10 ng (Sn) L−1. The repeatability is 3–10%, according to the extraction used. Analyses of reference sediment, fresh and waste waters confirm the suitability and capabilities of GC–ICP–AES for organotin determination in the environment. The statistical approach has been demonstrated to be a powerful methodological tool, enhancing the experimental part by providing reliable analytical results.
引用
收藏
页码:226 / 235
页数:9
相关论文
共 29 条
  • [1] Fent G(1996)undefined Crit Rev Toxicol 26 1-29
  • [2] Chau M(1997)undefined Water Qual Res J Can 32 453-undefined
  • [3] Maguire undefined(1991)undefined Water Pollut Res J Can 26 243-undefined
  • [4] Donard undefined(1993)undefined Water Res 27 1085-undefined
  • [5] Lespes undefined(2001)undefined L'Eau, L'industrie, les Nuisances 39 24-undefined
  • [6] Potin-Gautier undefined(2000)undefined J Chromatogr A 896 149-undefined
  • [7] Bancon-Montigny undefined(1998)undefined J Chromatogr A 826 67-undefined
  • [8] Lespes undefined(2000)undefined Analyst 125 263-undefined
  • [9] Aguerre undefined(2000)undefined J Chromatogr A 873 63-undefined
  • [10] Millan undefined(1994)undefined Anal Chem 66 160-undefined