Repeatability, reproducibility, and comparison of ocular biometry using a new optical coherence tomography-based system and another device

被引:0
|
作者
Adam Wylęgała
Bartłomiej Bolek
Robert Mazur
Edward Wylęgała
机构
[1] Railway Hospital,Ophthalmology Department
[2] Zabrze Medical University of Silesia,II School of Medicine with the Division of Dentistry
来源
Scientific Reports | / 10卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Precise measurement of axial length before cataract surgery is necessary for the proper lens implantation. We included 100 eyes of 56 patients in the study. The mean age was 41 (15–84 years). Measurements of axial length, anterior chamber depth (ACD) carried out with the new Revo NX were compared with those obtained with the IOLMaster 500. Interoperator testing was performed on 56 eyes of 56 participants. To test repeatability, axial length, ACD, central corneal thickness, and lens thickness were used. Inter-operator reproducibility was also assessed. The results were evaluated using Bland–Altman analyses. The mean ACD measured with the IOLMaster and Revo NX was 3.41 and 3.40 mm p = 0.467, respectively. The interclass correlation was excellent at the level of 0.975. ICC for axial length values was 0.999, and the mean was equal to 23.47 for the new device and 23.48 for IOLMaster. ICC for Inter-operator repeatability was higher than 0.99 in all parameters. Revo NX showed a very high level of repeatability with ICC ranging from 0.9929 for central corneal thickness to 0.9997 for axial length. Both devices showed excellent agreement and differences that are insignificant, which suggests that they can be used interchangeably.
引用
收藏
相关论文
共 50 条
  • [21] Anterior Ocular Biometry Using 3-Dimensional Optical Coherence Tomography
    Fukuda, Shinichi
    Kawana, Keisuke
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    OPHTHALMOLOGY, 2009, 116 (05) : 882 - 889
  • [22] Ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers with segmental or equivalent refractive indices
    Omoto, Miki Kamikawatoko
    Torii, Hidemasa
    Masui, Sachiko
    Ayaki, Masahiko
    Tsubota, Kazuo
    Negishi, Kazuno
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [23] Reproducibility-Repeatability of Choroidal Thickness Calculation Using Optical Coherence Tomography
    Benavente-Perez, Alexandra
    Hosking, Sarah L.
    Logan, Nicola S.
    Bansal, Dheeraj
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (11) : 867 - 872
  • [24] Repeatability and Reproducibility of Macular Hole Size Measurements Using Optical Coherence Tomography
    Baumann, Carmen
    Almarzooqi, Ahmed
    Blobner, Katharina
    Zapp, Daniel
    Kirchmair, Katharina
    Schwer, Lydia S.
    Lohmann, Chris P.
    Kaye, Stephen B.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [25] Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low-Coherence Reflectometer
    Rohrer, Kaspar
    Frueh, Beatrice E.
    Waelti, Rudolf
    Clemetson, Isabelle A.
    Tappeiner, Christoph
    Goldblum, David
    OPHTHALMOLOGY, 2009, 116 (11) : 2087 - 2092
  • [26] Repeatability and Reproducibility of Quantitative Assessment of the Retinal Microvasculature Using Optical Coherence Tomography Angiography Based on Optical Microangiography
    ZHAO Qi
    YANG Wen Li
    WANG Xiao Na
    Ruikang K Wang
    YOU Qi Sheng
    CHU Zhong Di
    XIN Chen
    ZHANG Meng Yu
    LI Dong Jun
    WANG Zi Yang
    CHEN Wei
    LI Yi Feng
    CUI Rui
    SHEN Lin
    WEI Wen Bin
    BiomedicalandEnvironmentalSciences, 2018, 31 (06) : 407 - 412
  • [27] Repeatability and Reproducibility of Biometry and Keratometry Measurements Using a Noncontact Optical Low-Coherence Reflectometer and Keratometer
    Shammas, H. John
    Hoffer, Kenneth J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (01) : 55 - 61
  • [28] Repeatability and Reproducibility of Quantitative Assessment of the Retinal Microvasculature Using Optical Coherence Tomography Angiography Based on Optical Microangiography
    Zhao Qi
    Yang Wen Li
    Wang Xiao Na
    Wang, Ruikang K.
    You Qi Sheng
    Chu Zhong Di
    Xin Chen
    Zhang Meng Yu
    Li Dong Jun
    Wang Zi Yang
    Chen Wei
    Li Yi Feng
    Cui Rui
    Shen Lin
    Wei Wen Bin
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2018, 31 (06) : 407 - 412
  • [29] Repeatability and reproducibility of a new spectral-domain optical coherence tomography biometer and agreement with swept-source optical coherence tomography based biometer
    Li, Xin
    Lei, Chak Seng
    Ning, Rui
    Liu, Luze
    Chen, Aodong
    Yang, Xinning
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2025, 12 (01)
  • [30] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    ANNALS OF EYE SCIENCE, 2023, 8