Mechanical, Electrochemical and Biological Behavior of 3D Printed-Porous Titanium for Biomedical Applications

被引:0
作者
Morris D. [1 ]
Mamidi S.K. [1 ]
Kamat S. [1 ]
Cheng K.-Y. [1 ]
Bijukumar D. [1 ]
Tsai P.-I. [2 ]
Wu M.-H. [3 ,4 ]
Orías A.A.E. [5 ]
Mathew M.T. [1 ,5 ,6 ]
机构
[1] Department of Biomedical Science, The University of Illinois College of Medicine, Rockford, IL
[2] Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu
[3] Department of Orthopedics, Taipei Medical University Hospital, Taipei
[4] Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei
[5] Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
[6] Restorative Dentistry, University of Illinois At Chicago, Chicago, IL
关键词
3D printing; Additive manufacturing; Porosity; Titanium;
D O I
10.1007/s40735-020-00457-5
中图分类号
学科分类号
摘要
Porosity is a feature that can be designed into 3D printed parts, notably surgical implants, and porosity is associated with improved biocompatibility and osseointegration. It is imperative to evaluate the electrochemical behavior of 3D printed-porous Ti to identify the optimum porosity with low corrosion kinetics for biomedical applications. The objective of this study was to evaluate the corrosion kinetics, mechanical properties, and biocompatibility of 3D printed porous Titanium alloy metal. 3D printed porous Ti samples of 11 mm diameter and 7 mm thick with five porosity levels (0%, 20%, 40%, 60%, and 80%) were manufactured, mechanically tested, studied for characterization and Electrochemical behavior. The cell proliferations was also conducted on different groups for the examination of their biocompatibility, which might indicate the influence of porosity to the cellular activities. The results showed that increasing porosity corresponds with decreasing mechanical strength and increasing corrosion characteristics. Corrosion current, Icorr values ranged from 10−7 to 10−4 A, and Ecorr values ranged from + 100 to − 600 mV for all five porosity-level samples. Analysis of EIS data indicated that capacitance values ranged from 0.00025 to 0.0015F. In addition, sample porosity showed evidence of other corrosion forms such as crevice corrosion and intergranular corrosion. The results of cell proliferations demonstrated all groups of specimens are biocompatible and the ones with 0% and 40% porosity exhibited the highest increments of cells, implying their potential in biomedical application. The study revealed that 3D printed Ti samples with larger porosity were subjected to increased electrochemical corrosion. A porosity between 40 and 60% 3D printed porous Ti study sample was found optimum for the biomedical application. The development of future biomedical devices will have to maintain a balanced approach between the osseointegration of large porosities and increased corrosion tendencies to optimize safer devices through additive manufacturing or 3D printing for better patient outcomes. Further studies will evaluate 3D-printed tribocorrosion properties and biocompatibility via osteoblast culture. © 2021, The Author(s), under exclusive licence to Springer Nature Switzerland AG part of Springer Nature.
引用
收藏
相关论文
共 49 条
[1]  
Jones C.A., Beaupre L.A., Johnston D.W.C., Suarez-Almazor M., Total joint arthroplasties: current concepts of patient outcomes after surgery, Rheum Dis Clin N Am, 33, pp. 71-86, (2007)
[2]  
Harding P., Holland A.E., Delany C., Hinman R.S., Do activity levels increase after total hip and knee arthroplasty?, Clin Orthop, 472, pp. 1502-1511, (2014)
[3]  
Fitzgerald J.D., Et al., Patient quality of life during the 12 months following joint replacement surgery, Arthritis Care Res, 51, pp. 100-109, (2004)
[4]  
Okazak Y., Nishimura E., Nakada H., Kobayashi K., Surface analysis of Ti-15Zr-4Nb-4Ta alloy after implantation in rat tibia, Biomaterials, 22, pp. 599-607, (2001)
[5]  
Kurtz S., Ong K., Lau E., Mowat F., Halpern M., Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030, J Bone Jt Surg Am, 89, pp. 780-785, (2007)
[6]  
Iamthanaporn K., Chareancholvanich K., Pornrattanamaneewong C., Revision primary total hip replacement: causes and risk factors, J Med Assoc Thail Chotmaihet Thangphaet, 98, pp. 93-99, (2015)
[7]  
Hallab N.J., Cunningham B.W., Jacobs J.J., Spinal implant debris-induced osteolysis, Spine, 28, (2003)
[8]  
Mahomed N.N., Et al., Rates and outcomes of primary and revision total hip replacement in the United States medicare population, J. Bone Jt Surg Am, 85A, pp. 27-32, (2003)
[9]  
Zeng L., Xiang N., Wei B., A comparison of corrosion resistance of cobalt-chromium-molybdenum metal ceramic alloy fabricated with selective laser melting and traditional processing, J Prosthet Dent, 112, pp. 1217-1224, (2014)
[10]  
Heinl P., Korner C., Singer R.F., Selective electron beam melting of cellular titanium: mechanical properties, Adv Eng Mater, 10, pp. 882-888, (2008)