PET and SPECT imaging of the brain: a review on the current status of nuclear medicine in Japan

被引:0
作者
Tomohiro Kaneta
机构
[1] University of Tsukuba,Department of Advanced Molecular Imaging, Faculty of Medicine
来源
Japanese Journal of Radiology | 2020年 / 38卷
关键词
PET; SPECT; Brain; Japan;
D O I
暂无
中图分类号
学科分类号
摘要
Radiolabeled tracers allow visualization of not only perfusion, but receptors, function, and metabolism as well. Although spatial resolution is lower than that of computed tomography and magnetic resonance imaging, positron emission tomography (PET) and single photon emission computed tomography (SPECT) have great potential for target-specific imaging. In this review, we discuss several SPECT and PET tracers used in brain imaging, specifically focusing on tracers currently available, or developed, in Japan. Several important and sophisticated methods exist for analysis of brain PET and SPECT images. Two of them, quantitative cerebral blood flow measurement and voxel-based statistical analysis are discussed in this review. The former method, which employs acetazolamide loading, is useful for evaluation of the brain perfusion reserve for ischemic brain diseases. The latter is useful in diagnosing dementing diseases. Additionally, great strides have been made in the development of the technology used in the scanners. New SPECT systems based on cadmium–zinc–telluride, PET/MRI, and semiconductor PET/CT may provide higher spatial resolution with an acquisition time shorter than ever before. Such developments of both tracers and scanners can be integrated for unprecedented imagery of the brain, providing valuable insight into underlying causes of some fatal brain disorders.
引用
收藏
页码:343 / 357
页数:14
相关论文
共 540 条
  • [1] Tikofsky RS(1993)Radiopharmaceuticals for brain imaging: the technologist’s perspective J Nucl Med Technol. 21 57-60
  • [2] Trembath LA(1996)Evaluation of technetium-99m-ECD in childhood epilepsy J Nucl Med. 37 1106-1112
  • [3] Voslar AM(1996)A multicenter validation of regional cerebral blood flow quantitation using [123I]iodoamphetamine and single photon emission computed tomography J Cereb Blood Flow Metab. 16 781-793
  • [4] Menzel C(1990)Validation studies of iodine-123-iodoamphetamine as a cerebral blood flow tracer using emission tomography J Nucl Med. 31 1364-1369
  • [5] Steidele S(1982)Quantifying local cerebral blood flow by J Nucl Med 23 196-203
  • [6] Grünwald F(1997)-isopropyl-p[I-123]iodo amphetamine (IMP) tomography J Nucl Med. 38 1102-1108
  • [7] Hufnagel A(1995)Regional cerebral blood flow measurement with iodine-123-IMP autoradiography: normal values, reproducibility and sensitivity to hypoperfusion Eur J Nucl Med. 22 633-637
  • [8] Pavics L(1983)A quantitative approach to technetium-99m ethyl cysteinate dimer: a comparison with technetium-99m hexamethylpropylene amine oxime J Cereb Blood Flow Metab. 3 1-7
  • [9] Elger CE(2004)Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data Ann Nucl Med. 18 115-121
  • [10] Iida H(2000)Cerebral hemodynamics and metabolism in adult moyamoya disease: comparison of angiographic collateral circulation J Nucl Med. 41 1836-1841