Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns

被引:0
作者
M. Anbarasu
K. Kanagarasu
S. Sukumar
机构
[1] Government College of Engineering,Department of Civil Engineering
来源
Materials and Structures | 2015年 / 48卷
关键词
Battened column; Built-up column; CFS columns; Direct strength method; Distortional buckling; Numerical simulation; Web stiffened lipped channel;
D O I
暂无
中图分类号
学科分类号
摘要
Cold-formed steel built-up sections are commonly used as compression elements to carry larger loads and over longer spans when a single individual section is insufficient. This paper reports a numerical study of the cold-formed steel built-up web stiffened lipped channel sections under axial compression. The built-up sections are formed by two identical lipped channels placed back to back with batten plates and are connected by self-driving screw. The Finite element model is developed by ABAQUS software and the model is validated with the results available in the literature. Three types of web stiffened lipped channel cross section have been chosen for the study, based on the AISI-S100:2007 Geometric limitations. The parametric study is extended by the validated model for various slenderness ratios. The column strength predicted by the finite element analysis is compared with the design column strengths predicted by direct strength method (DSM). Based on this study a recommendation is proposed to DSM.
引用
收藏
页码:4029 / 4038
页数:9
相关论文
共 50 条
[31]   Simplified design method of cold-formed steel columns with built-up box sections [J].
Zhou, Xuhong ;
Xiang, Yi ;
Shi, Yu ;
Xu, Lei ;
Zou, Yuxuan .
ENGINEERING STRUCTURES, 2021, 228
[32]   Buckling behavior of closed built-up cold-formed steel columns under compression [J].
Craveiro, Helder D. ;
Rahnavard, Rohola ;
Laim, Luis ;
Simoes, Rui A. ;
Santiago, Aldina .
THIN-WALLED STRUCTURES, 2022, 179
[33]   Numerical simulation and specification provisions for cruciform cold-formed steel built-up columns [J].
Lu, Wei-Bo ;
Chen, Ming ;
Shi, Yu ;
Li, Bu-Shuan .
STRUCTURES, 2023, 51 :484-497
[34]   Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns [J].
Lu, Yan ;
Zhou, Tianhua ;
Li, Wenchao ;
Wu, Hanheng .
THIN-WALLED STRUCTURES, 2017, 112 :125-139
[35]   Experimental investigation on distortional performance of cold-formed steel built-up channel columns with web-stiffeners under eccentric compression [J].
He Z. ;
Yang G. ;
Zhou X. ;
Peng S. .
Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (10) :237-248
[36]   Design of locally buckling cold-formed steel built-up columns formed unlipped channel sections [J].
Mahar, Akshay Mangal ;
Jayachandran, S. Arul ;
Mahendran, Mahen .
THIN-WALLED STRUCTURES, 2022, 174
[37]   Web crippling design of cold-formed steel built-up I-sections [J].
He, Jun ;
Young, Ben .
ENGINEERING STRUCTURES, 2022, 252
[38]   Design of cold-formed steel built-up sections with web perforations subjected to bending [J].
Wang, Liping ;
Young, Ben .
THIN-WALLED STRUCTURES, 2017, 120 :458-469
[39]   COMPRESSION TESTS OF COLD-FORMED STEEL BUILT-UP CLOSED SECTIONS WITH WEB STIFFENERS [J].
Zhang, Jia-Hui ;
Young, Ben .
STEEL AND ALUMINIUM STRUCTURES, 2016,
[40]   Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP [J].
Naganathan, Sivakumar ;
Chakravarthy, H. G. Nahushananda ;
Anuar, Noor Amalina ;
Kalavagunta, Sreedhar ;
Bin Mustapha, Kamal Nasharuddin .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (02) :415-424