A study of continuous-wave two-frequency NQR

被引:0
|
作者
J. Pirnat
J. Lužnik
Z. Trontelj
机构
[1] Institute of Mathematics,Physics Department, Faculty of Mathematics and Physics
[2] Physics and Mechanics,undefined
[3] University of Ljubljana,undefined
来源
关键词
Nuclear Quadrupole Resonance; Population Difference; Nuclear Quadrupole Resonance Frequency; Quadrupole Nucleus; Nuclear Quadrupole Resonance Spectrum;
D O I
暂无
中图分类号
学科分类号
摘要
A simple continuous-wave parallel to pulse version of a multifrequency nuclear quadrupole resonance (NQR) device was constructed and tested: two orthogonal radio-frequency (RF) fields were applied simultaneously at two suitable frequencies to a multilevel quadrupole probe (I⋝1). A modified superregenerative NQR oscillator-detector (SRO) was utilized. An additional coil and RF source were used to irradiate the sample at the second frequency. After tuning the SRO to a chosen NQR line, the signal proportional to the population difference of the corresponding pair of energy levels was monitored. When another suitable transition was saturated simultaneously, sharing one level with the monitored line, the corresponding population change was also reflected in the first signal intensity change. The phenomenon was examined for Sb nuclei in Sb2S3 powder at room temperature.
引用
收藏
页码:43 / 53
页数:10
相关论文
共 50 条
  • [11] Two-Frequency Planar Gradiometer for Distant NQR Detection of Explosives
    Rustem R. Khusnutdinov
    G. V. Mozzhukhin
    A. B. Konov
    Y. Ozturk
    B. Z. Rameev
    Applied Magnetic Resonance, 2021, 52 : 1787 - 1797
  • [12] Theory of two-frequency excitation in14N NQR
    D. Ya. Osokin
    R. R. Khusnutdinov
    Applied Magnetic Resonance, 2003, 24 : 145 - 156
  • [13] Ferromagnetic distortion of a two-frequency wave
    Kalb, RM
    Bennett, WR
    BELL SYSTEM TECHNICAL JOURNAL, 1935, 14 : 322 - 359
  • [14] Two-frequency continuous wave ultrasonic system for temperature measurement in an infant incubator
    Young, M.S., 2001, Institute of Biomedical Engineering (13):
  • [15] Linear two-frequency laser-diode-pumped continuous-wave Nd3+:YAG laser with a phase-anisotropic cavity
    Shananin, RA
    Petrovskiy, VN
    Protsenko, ED
    Shatrova, EA
    Soloviev, DI
    OPTICS COMMUNICATIONS, 1997, 143 (4-6) : 241 - 246
  • [16] Two-frequency multiple-pulse sequences in nitrogen-14 NQR
    Osokin, DY
    Khusnutdinov, RR
    Shagalov, VA
    APPLIED MAGNETIC RESONANCE, 2004, 25 (3-4) : 513 - 521
  • [17] Two-frequency multiple-pulse sequences in nitrogen-14 NQR
    D. Ya. Osokin
    R. R. Khusnutdinov
    V. A. Shagalov
    Applied Magnetic Resonance, 2004, 25 : 513 - 521
  • [18] RADIOFREQUENCY COIL DESIGN AND SIGNAL INTENSITY FOR CONTINUOUS-WAVE NQR AND NMR SPECTROMETERS
    LUZNIK, J
    TRONTELJ, Z
    JOURNAL OF MAGNETIC RESONANCE, 1978, 30 (03) : 551 - 556
  • [19] Application of the spherical tensor method for Two-Frequency pure NQR of spinI=1 nuclei
    G. V. Mozjoukhine
    Applied Magnetic Resonance, 2002, 22 : 31 - 46
  • [20] The reference wave solution for a two-frequency wave propagating in a random medium
    Bronshtein, A
    Mazar, R
    WAVES IN RANDOM MEDIA, 2002, 12 (03): : 267 - 277