A review of electrodes for the electrical brain signal recording

被引:66
作者
Im C. [1 ,2 ]
Seo J.-M. [2 ,3 ]
机构
[1] BK21 Plus Transformative Training Program for Creative Mechanical and Aerospace Engineers, Seoul National University, Seoul
[2] Department of electrical and computer engineering, and Institute of Engineering, Seoul National University, Seoul
[3] Biomedical Research Institute, Seoul National University Hospital, Seoul
关键词
ECoG; EEG; LFP; Multi-unit recording; Neural recording system; Recording electrode; Single-unit recording;
D O I
10.1007/s13534-016-0235-1
中图分类号
学科分类号
摘要
Brain is complex organ composed of numerous glial cells and neurons to convey information using chemical and electrical signals. Neural interface technology using the electrical brain signals has attracted great attention for the clinical and experimental applications. Electrode as the neural interface is the most important part in stimulating neural cells or recording neural activities. In this paper, we provide an overview of electrodes for recording the electrical brain signal. The noninvasive electrodes are primarily used to capture electroencephalogram (EEG) from outside the skull while the implantable electrodes are employed to measure electrocorticogram (ECoG), local field potential (LFP) or spike activity. Recent progress in microfabrication technology enables the development of on-board electrode that combines the entire signal processing including amplification, filtering, and digitization. This will contribute to diagnostic and therapeutic application of the neural interface for restoring physical, psychological and social functions by improving motor, sensory or cognitive abilities. © 2016, Korean Society of Medical and Biological Engineering and Springer.
引用
收藏
页码:104 / 112
页数:8
相关论文
共 97 条
[91]  
Brazier M.A., Recordings from large electrodes, Methods Med Res., 9, pp. 405-432, (1961)
[92]  
Seymour J.P., Kipke D.R., Neural probe design for reduced tissue encapsulation in CNS, Biomaterials., 28, 25, pp. 3594-3607, (2007)
[93]  
Kotzar G., Freas M., Abel P., Fleischman A., Roy S., Zorman C., Moran J.M., Melzak J., Evaluation of MEMS materials of construction for implantable medical devices, Biomaterials., 23, 13, pp. 2737-2750, (2002)
[94]  
Lee S.W., Seo J.M., Ha S., Kim E.T., Chung H., Kim S.J., Development of microelectrode arrays for artificial retinal implants using liquid crystal polymers, Invest Ophth Vis Sci., 50, 12, pp. 5859-5866, (2009)
[95]  
Lect Notes Artif Int., (2007)
[96]  
Lee S.B., Lee B., Kiani M., Mahmoudi B., Gross R., Ghovanloo M., An inductively-powered wireless neural recording system with a charge sampling analog front-end, IEEE Sens J., 16, 2, pp. 475-484, (2016)
[97]  
Rhew H.-G., Jeong J., Fredenburg J.A., Dodani S., Patil P.G., Flynn M.P., A fully self-contained logarithmic closed-loop deep brain stimulation SoC with wireless telemetry and wireless power management, IEEE J Solid-St Circ., 49, 10, pp. 2213-2227, (2014)