A review of electrodes for the electrical brain signal recording

被引:66
作者
Im C. [1 ,2 ]
Seo J.-M. [2 ,3 ]
机构
[1] BK21 Plus Transformative Training Program for Creative Mechanical and Aerospace Engineers, Seoul National University, Seoul
[2] Department of electrical and computer engineering, and Institute of Engineering, Seoul National University, Seoul
[3] Biomedical Research Institute, Seoul National University Hospital, Seoul
关键词
ECoG; EEG; LFP; Multi-unit recording; Neural recording system; Recording electrode; Single-unit recording;
D O I
10.1007/s13534-016-0235-1
中图分类号
学科分类号
摘要
Brain is complex organ composed of numerous glial cells and neurons to convey information using chemical and electrical signals. Neural interface technology using the electrical brain signals has attracted great attention for the clinical and experimental applications. Electrode as the neural interface is the most important part in stimulating neural cells or recording neural activities. In this paper, we provide an overview of electrodes for recording the electrical brain signal. The noninvasive electrodes are primarily used to capture electroencephalogram (EEG) from outside the skull while the implantable electrodes are employed to measure electrocorticogram (ECoG), local field potential (LFP) or spike activity. Recent progress in microfabrication technology enables the development of on-board electrode that combines the entire signal processing including amplification, filtering, and digitization. This will contribute to diagnostic and therapeutic application of the neural interface for restoring physical, psychological and social functions by improving motor, sensory or cognitive abilities. © 2016, Korean Society of Medical and Biological Engineering and Springer.
引用
收藏
页码:104 / 112
页数:8
相关论文
共 97 条
[1]  
Caton R., Electrical currents of the brain, J Nerv Ment Dis., 2, 4, (1875)
[2]  
Haas L.F., Hans Berger (1873–1941), Richard Caton (1842–1926), and electroencephalography, J Neurol Neurosurg PS., 74, 1, (2003)
[3]  
Woldring S., Dirken M.N., Spontaneous unit-activity in the superficial cortical layers, Acta Physiol Pharm N., 1, 3, pp. 369-379, (1950)
[4]  
Hubel D.H., Wiesel T.N., Receptive fields of single neurones in the cat’s striate cortex, J Physiol., 148, 3, pp. 574-591, (1959)
[5]  
Marg E., Adams J.E., Indwelling multiple micro-electrodes in the brain, Electroen Clin Neuro., 23, 3, pp. 277-280, (1967)
[6]  
Asano E., Juhasz C., Shah A., Muzik O., Chugani D.C., Shah J., Sood S., Chugani H.T., Origin and propagation of epileptic spasms delineated on electrocorticography, Epilepsia., 46, 7, pp. 1086-1097, (2005)
[7]  
Creutzfeldt O.D., Watanabe S., Lux H.D., Relations between EEG phenomena and potentials of single cortical cells, I. Evoked responses after thalamic and erpicortical stimulation. Electroencephalogr Clin Neurophysiol., 20, 1, pp. 1-18, (1966)
[8]  
Creutzfeldt O.D., Watanabe S., Lux H.D., Relations between EEG phenomena and potentials of single cortical cells, II. Spontaneous and convulsoid activity. Electroencephalogr Clin Neurophysiol., 20, 1, pp. 19-37, (1966)
[9]  
Klee M.R., Offenloch K., Tigges J., Cross-correlation analysis of electroencephalographic potentials and slow membrane transients, Science., 147, 3657, pp. 519-521, (1965)
[10]  
Tallgren P., Vanhatalo S., Kaila K., Voipio J., Evaluation of commercially available electrodes and gels for recording of slow EEG potentials, Clin Neurophysiol., 116, 4, pp. 799-806, (2005)