Experimental and numerical analyses of the pull-out response of a steel post/bovine bone cementless fixation

被引:0
作者
Khaled Gammoudi
Mohamed Kharrat
Maher Dammak
机构
[1] Electromechanical Systems Laboratory,National Engineering School of Sfax
[2] University campus Sidi Ahmed Zarrouk,Higher Institute of Technological Studies of Gafsa
[3] University campus Sidi Ahmed Zarrouk,Faculty of Sciences of Gafsa
[4] Preparatory Institute for Engineering Studies of Sfax,undefined
来源
Journal of Bionic Engineering | 2012年 / 9卷
关键词
total knee arthroplasty; bovine bone/steel post fixation; interference fit; pull-out strength; FEM;
D O I
暂无
中图分类号
学科分类号
摘要
Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study. Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia. Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel. A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component. Pull-out experiments were carried out for different initial interference fits. Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results. At the post/bone interface, Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient. It was found that the FEM results of the ultimate force are in good agreement with the experimental results. The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.
引用
收藏
页码:501 / 507
页数:6
相关论文
共 80 条
  • [1] Lombardi A V(2007)Evolution of tibial fixation in total knee arthroplasty The Journal of Arthroplasty 22 25-29
  • [2] Berasi C C(2001)The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty The Journal of Arthroplasty 16 759-767
  • [3] Berend K R(2006)Tibial fixation without screws in cementless total knee arthroplasty The Journal of Arthroplasty 21 237-241
  • [4] Jazrawi L M(2006)Surface cementation of stemmed tibial components in primary total knee arthroplasty The Journal of Arthroplasty 21 353-357
  • [5] Bai B(2007)Tibial component fixation in total knee arthroplasty: a comparison of pegged and stemmed designs The Journal of Arthroplasty 22 670-678
  • [6] Kummer F J(2011)Uncemented tibial fixation total knee arthroplasty The Journal of Arthroplasty 26 41-44
  • [7] Hiebert R(2010)The effect of the trabecular microstructure on the pullout strength of suture anchors Journal of Biomechanics 43 1953-1959
  • [8] Stuchin S A(2011)Mechanical testing and osteointegration of titanium implant with calcium phosphate bone cement and autograft alternatives Journal of the Mechanical Behavior of Biomedical Materials 4 1186-1195
  • [9] Cooke C(2010)Pullout strength of suture anchors: Effect of mechanical properties of trabecular bone Journal of Biomechanics 43 1138-1145
  • [10] Walter W K(2009)Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws Clinical Biomechanics 24 781-785